3.4.11 Heating and insulation
Insulation
Insulation
Insulation
Insulation
The meter can be insulated to a maximum depth as shown (A). Do not insulate above this depth
as this will cause the electronics to overheat.
Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
If the meter has been ordered with a heating jacket, it will be supplied with DN15 PN40 to EN
1092-1 or 1/2¨ ASME150 flange connections.
Connecting / using the heating jacket
• Use rigid or reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket / loop material is SS316.
• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can
cause crevice corrosion in Stainless Steel.
Insulation
S08
S10
S15
S25
S50
S80
S100 S150 S200 S250
Dimension A [mm]
100
100
100
100
100
100
100
100
100
100
Dimension A [inches]
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
Figure 3-1: The loop inside the heating jacket, carries the heating medium.