3.4.11 Heating and insulation

Insulation

Insulation

Insulation

Insulation

The meter can be insulated to a maximum depth as shown (A). Do not insulate above this depth
as this will cause the electronics to overheat.

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

If the meter has been ordered with a heating jacket, it will be supplied with DN15 PN40 to EN
1092-1 or 1/2¨ ASME150 flange connections.

Connecting / using the heating jacket

• Use rigid or reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket / loop material is SS316.
• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can

cause crevice corrosion in Stainless Steel.

Insulation

S08

S10

S15

S25

S50

S80

S100 S150 S200 S250

Dimension A [mm]

100

100

100

100

100

100

100

100

100

100

Dimension A [inches]

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

Figure 3-1: The loop inside the heating jacket, carries the heating medium.