TECHNICAL DATA

6

33

OPTIMASS 6000

www.krohne.com

07/2014 - 4001894003 - MA OPTIMASS 6000 R03 en

Materials

Stainless Steel (316 / 316L) meter

Stainless Steel (316 / 316L) meter

Stainless Steel (316 / 316L) meter

Stainless Steel (316 / 316L) meter

Measuring tubes / Flanges

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Spigots

Stainless Steel CF3M (1.4409)

Bridge

Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified or AISI 316 /

316L (1.4401 / 1.4404) dual certified

Outer casing

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Stainless Steel (S31803) meter

Stainless Steel (S31803) meter

Stainless Steel (S31803) meter

Stainless Steel (S31803) meter

Measuring tubes / Flanges

Stainless Steel UNS 31803 (1.4462)

Spigots

Stainless Steel J92205 (1.4470)

Bridge

Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified or AISI 316 /

316L (1.4401 / 1.4404) dual certified

Outer casing

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Hastelloy

Hastelloy

Hastelloy

Hastelloy® C22 meter

C22 meter

C22 meter

C22 meter

Measuring tubes / raised face

Hastelloy® C22

(Backing) flanges

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Bridge

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Outer casing

Stainless Steel AISI 316L (1.404) dual certified

Heating jacket version

Heating jacket version

Heating jacket version

Heating jacket version

Heating loop and insulation jacket

Stainless Steel AISI 316 (1.4401)

All versions

All versions

All versions

All versions

Junction box (remote version)

Die-cast Aluminium (polyurethane coating)

Optional Stainless Steel 316 (1.4401)

Process connections

Flange

Flange

Flange

Flange

DIN (EN 1092-1 2007)

DN10…300 / PN16…160

ASME (B616.5)

½

...12" / ASME 150…1500

JIS (2220 2001)

10A...300A / 10...20K (10K maximum allowable temperature 300°C / 572°F)

Hygienic (08...50 only)

Hygienic (08...50 only)

Hygienic (08...50 only)

Hygienic (08...50 only)

Tri-clover

¾

...3"

Tri-clamp DIN 32676

DN15..80

Tri-clamp ISO 2852

1...3"

DIN 11864-2 Form A (female)

DN15...80

Male thread DIN 11851 (threaded

sanitary connection)

DN15...80

Male thread SMS

25...76 mm / 1...3"

Electrical connections

Electrical connections

For full details, including: power supply, power consumption etc., see

technical data for the relevant signal converter.

I/O

For full details of I/O options, including data streams and protocols, see

technical data for the relevant signal converter.

MA_OPTIMASS_6000_en_140717_4001894003_R03.book Page 33 Thursday, July 17, 2014 3:27 PM