Technical data – KROHNE OPTIMASS 2000 EN User Manual
Page 36

6
TECHNICAL DATA
36
OPTIMASS 2000
www.krohne.com
10/2010 - 4000810002- MA OPTIMASS 2000 R02 en
ATEX (acc. 94/9/EC) temperature limits
Maximum end loadings
Ambient temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temp. class
Max. surface
temp. °C
OPTIMASS 2000 / 2010C with or without
heating jacket / insulation
40
65
T6
T80
75
T5
T95
110
T4
T130
130
T3-T1
T150
65
75
T5
T95
110
T4
T130
130
T3-T1
T150
OPTIMASS 2300C Aluminium converter
housing - with or without heating jacket
/ insulation
40
50
T6
T80
65
T5
T95
100
T4
T130
130
T3-T1
T160
50
65
T5
T95
100
T4-T1
T130
60
60
T4-T1
T90
65
1
65
T4-T1
T95
OPTIMASS 2300C Stainless Steel
converter housing - with or without
heating jacket / insulation
40
50
T6
T80
65
T5
T95
100
T4
T130
120
T3-T1
T150
50
65
T5
T95
75
T4-T1
T105
55
55
T5-T1
T85
1 depending on I/O option. Please call for more information.
S100
S150
S250
Flanges
Flanges
Flanges
Flanges
20°C
40 barg
150kN
350kN
550kN
100 barg
100kN
120kN
60kN
150 barg
180 barg
130°C
32 barg
150kN
280kN
400kN
80 barg
60kN
50kN
50kN
115 barg
130 barg
Hygienic (all connections)
Hygienic (all connections)
Hygienic (all connections)
Hygienic (all connections)
130°C
10 barg
5kN
-
-
MA_OPTIMASS2000_en_101022_4000810002_R02.book Page 36 Monday, November 22, 2010 5:47 PM
- BATCHFLUX 5500 C Quickstart EN (20 pages)
- IFC 050 Converter Quickstart EN (28 pages)
- IFC 100 Converter Quickstart EN (32 pages)
- IFC 300 Converter Quickstart EN (68 pages)
- OPTIFLUX 1000 Quickstart EN (20 pages)
- OPTIFLUX 2000 Quickstart EN (24 pages)
- OPTIFLUX 4000 Quickstart EN (24 pages)
- OPTIFLUX 4040C Quickstart EN (16 pages)
- OPTIFLUX 5000 Flange Quickstart EN (20 pages)
- OPTIFLUX 5000 Sandwich Quickstart EN (20 pages)
- OPTIFLUX 6000 Quickstart EN (28 pages)
- OPTIFLUX 7300 Quickstart EN (24 pages)
- OPTIPROBE Quickstart EN (16 pages)
- TIDALFLUX 2300 F EN (44 pages)
- TIDALFLUX 2300 F Quickstart EN (24 pages)
- WATERFLUX 3000 EN (40 pages)
- WATERFLUX 3000 Quickstart EN (24 pages)
- WATERFLUX 3070 EN (80 pages)
- WATERFLUX 3070 Quickstart EN (32 pages)
- USB ADAPTER PLUS EMF EN (16 pages)
- IFC 050 Converter Modbus EN (20 pages)
- IFC 100 Converter FOUNDATION FIELDBUS EN (64 pages)
- IFC 100 Converter Modbus EN (20 pages)
- IFC 300 Converter FOUNDATION FIELDBUS EN (60 pages)
- IFC 300 Converter HART 0102 EN (20 pages)
- IFC 300 Converter HART 0201 EN (23 pages)
- IFC 300 Converter Modbus EN (24 pages)
- IFC 300 Converter PROFIBUS PA DP EN (40 pages)
- OPTIFLUX 2000-4000 IECEx EN (16 pages)
- OPTIFLUX 2000-4000-5000-6000-7300-IFC 300 Ex EN (40 pages)
- OPTIFLUX 2000-4000-5000-6000 -IFC 100 Ex EN (24 pages)
- OPTIFLUX 4040 C Ex EN (20 pages)
- OPTIFLUX x300 Ex Zone2 EN (1 page)
- H250 M9 ES EN (36 pages)
- VA 40-VA 45 EN (36 pages)
- H250 M10 ATEX II2G Ex d EN (16 pages)
- H250 M10 ATEX II3D Ex t EN (16 pages)
- H250 M40 ATEX II2D Ex t-II2G Ex d EN (20 pages)
- H250 M40 ATEX II2G Ex i EN (20 pages)
- H250 M40 ATEX II3G Ex nA EN (20 pages)
- H250 M40 Ex II2G Reed EN (2 pages)
- H250 M9 ATEX II2G Ex i EN (16 pages)
- H250 M9S ATEX II3D Ex t-II3G Ex nA EN (20 pages)
- M8E Converter HART 0101 EN (13 pages)
- DK 32-DK 34 ATEX II2G Ex i EN (16 pages)