beautypg.com

Technical data, 2 technical data tables – KROHNE OPTITEMP Compact sensors User Manual

Page 33

background image

TECHNICAL DATA

7

33

OPTITEMP TRA-CXX

www.krohne.com

02/2014 - 4003290501 - MA OPTITEMP TRA-Cxx R01 en

7.2 Technical data tables

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Measuring the temperature of gases, liquids, vapours and solid

bodies in industrial processes. The devices are particularly suited to

liquids with low viscosity, water and chemicals with low

corrosiveness as well as saturated steam and superheated steam.

Measuring principle

Contact sensor

Measured value

Temperature

Design

Modular design

Industrial temperature sensors consist of several components which,

together, form a thermometer assembly:

Thermowell

Housing

Electrical connection

Transmitter (built in or rail mounted )

Signal converter

Built-in analog transmitter, OPTITEMP OEM 201

Analogue or digital temperature transmitter in the TT family as rail-

mount transmitter.

Sensor

Pt100 RTD as thin layer (TF), class A with a characteristic according

to DIN EN 60751.

Surface roughness(only valid for

TRA-C10)

Ra 0.8, Ra <0.8 electropolished available on request

Measuring range

Refer to "Operating conditions".

Measuring accuracy

Reference conditions

Ambient temperature: +23°C / +73.4°F (fluctuations due to air

pressure and density have no impact on measuring accuracy).

Maximum measuring error

More detailed information in the subsection "Measurement Error"

(also in the "Technical data" section). The maximum measurement

error also depends on the type of sensor:

Sensor element with Pt100 RTD: measurement error in accordance
with tolerance class A, according to DIN EN 60751.

Long term stability for built-in

transmitter

±0.1% of span per year

Influence of ambient for bulit in

transmitter

Max. of ±0.01°C or ±0.01% of span per °C

Max. of ±0.01°F or ±0.006% of span per °F

Response time for built in

transmitter

< 10 ms

.book Page 33 Friday, February 7, 2014 9:17 AM