Technical data, 2 technical data tables – KROHNE OPTITEMP Compact sensors User Manual
Page 33

TECHNICAL DATA
7
33
OPTITEMP TRA-CXX
www.krohne.com
02/2014 - 4003290501 - MA OPTITEMP TRA-Cxx R01 en
7.2 Technical data tables
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Application range
Measuring the temperature of gases, liquids, vapours and solid
bodies in industrial processes. The devices are particularly suited to
liquids with low viscosity, water and chemicals with low
corrosiveness as well as saturated steam and superheated steam.
Measuring principle
Contact sensor
Measured value
Temperature
Design
Modular design
Industrial temperature sensors consist of several components which,
together, form a thermometer assembly:
•
Thermowell
•
Housing
•
Electrical connection
•
Transmitter (built in or rail mounted )
Signal converter
Built-in analog transmitter, OPTITEMP OEM 201
Analogue or digital temperature transmitter in the TT family as rail-
mount transmitter.
Sensor
Pt100 RTD as thin layer (TF), class A with a characteristic according
to DIN EN 60751.
Surface roughness(only valid for
TRA-C10)
Ra 0.8, Ra <0.8 electropolished available on request
Measuring range
Refer to "Operating conditions".
Measuring accuracy
Reference conditions
Ambient temperature: +23°C / +73.4°F (fluctuations due to air
pressure and density have no impact on measuring accuracy).
Maximum measuring error
More detailed information in the subsection "Measurement Error"
(also in the "Technical data" section). The maximum measurement
error also depends on the type of sensor:
•
Sensor element with Pt100 RTD: measurement error in accordance
with tolerance class A, according to DIN EN 60751.
Long term stability for built-in
transmitter
±0.1% of span per year
Influence of ambient for bulit in
transmitter
Max. of ±0.01°C or ±0.01% of span per °C
Max. of ±0.01°F or ±0.006% of span per °F
Response time for built in
transmitter
< 10 ms
.book Page 33 Friday, February 7, 2014 9:17 AM