INSTALLATION

18

OPTITEMP TRA-CXX

www.krohne.com

02/2014 - 4003290501 - MA OPTITEMP TRA-Cxx R01 en

3.4.1 Possible installations

Installations include the parameters "installation site", "installation angle" and "insertion
length". Depending on the space available and the diameter of the pipe, three installations are
recommended for pipes with flowing product:

• Small pipe diameter: Installation directly against the direction of flow in a bend in the

pipe (1).

• Small pipe diameter: Installation diagonally against the direction of flow, if a bend in the pipe

is available (2).

• Large pipe diameter: Vertical installation, if flow-induced periodic vortex shedding does not

cause the thermometer to vibrate in its resonance frequency (3).

Figure 3-1: Recommended installations

.book Page 18 Friday, February 7, 2014 9:17 AM