beautypg.com

KROHNE ALTOFLUX IFM x080 K ATEX EN User Manual

Page 5

background image

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx

5

For details see the EC-type Examination Certificate in Sect. 8.1 of these instructions .

Primary head
The primary head contains two field coils (see table for type of protection) and two electrodes in
type of protection intrinsic safety category "ib" according to EN 50020.

Types of protection of primary head

Meter size

Type of protection
Housing:

Flameproof enclosure "d" according to EN 50018

DN25 up to DN150

Electrodes:

Intrinsic safety "ib" according to EN 50020

Field coils:

Increased safety "e" according to EN 50019

DN200 and larger

Electrodes:

Intrinsic safety "ib" according to EN 50020

NOTE:

The intrinsically safe electrode circuits of the IFM 4080K/…-EEx compact flowmeter
are only internal circuits and not accessible for the customer


Data plates of ALTOFLUX IFM 4080 K

IFM 4080 K … EEx

IFM 4080 K / i … EEx

10VA Um=253V

AMBIENT TEMPERATURE: -40...+60%%DC.

SEE CERTIFICATE FOR MAXIMUM TEMPERATURES.

DO NOT OPEN ENCLOSURE WHEN ENERGIZED !

MAX. SHORT-CIRCUIT CURRENT OF MAINS:

ENCLOSURE: T6 %%242 20 MIN.; T5 %%242 11 MIN.

WAITING TIME BEFORE OPENING OF THE FLAMEPROOF

INTRINSICALLY SAFE CIRCUITS: ELECTRODE CIRCUIT,

ONLY INTERNAL CONNECTIONS.

IFM 4080 K-EEx

SPACE FOR ADDITIONAL DATA

Kerkeplaat 12

KEMA 01 ATEX 2200 X

3313 LC Dordrecht
The Netherlands

48-63Hz

POWER

SERIAL NO.

+

Vac

Altometer

II 2GD EEx d

TYPE

T85...180%%DC

A

%

% -

Vdc

8W

-25%

+30%

[ib] IIC T6...T3

2002

IP65/67

PRODUCTION

YEAR OF

0344

Term. 24Vac,+10%/-15%,48-63Hz,10W

Term. 100...230Vac,+10%/-15%

24Vdc,+30%/-25%,10W,Um=253V

48-63Hz,8W,Um=253V

AMBIENT TEMPERATURE: -20...+60%%DC.

DO NOT OPEN ENCLOSURE WHEN ENERGIZED !

MAX. SHORT-CIRCUIT CURRENT OF MAINS:

Electrode circuit: only internal connections

Active output

Co=132nF; Lo=4mH;

Uo=23.5V; Io=98mA; Po=0.6W

Passive output

Ci=5nF; Li=0;

Ui=30V; Ii=300mA; Pi=4.2W

Ci=5nF; Li=0;

Ui=30V; Ii=250mA; Pi=1.0W

Passive output

INTRINSICALLY SAFE CIRCUITS

ENCLOSURE: T6 %%242 20 MIN.; T5 %%242 11 MIN.

WAITING TIME BEFORE OPENING OF THE FLAMEPROOF

SEE CERTIFICATE FOR MAXIMUM TEMPERATURES.

IFM 4080 K/i-EEx

Kerkeplaat 12

KEMA 01 ATEX 2200 X

3313 LC Dordrecht
The Netherlands

T

I /I

I+/I

B1+/B1

T

D/D

B2/B2

B1/B1

T

T

%%uTerm.

1L ,0L

L, N

POWER

SERIAL NO.

~

~

Altometer

II 2GD EEx d

TYPE

IP65/67

EEx ia IIC

EEx ia IIC

EEx ia IIC

EEx ib IIC

A

T85...180%%DC

[ib] [ia] IIC T6...T3

2002

PRODUCTION

YEAR OF

0344