Part B IFC 210 Signal converter Sect. 4.2

05/2002

IFC 210 E 25

Fct.

Display-Texts

Description and settings

Field Frequenz

Set Magnetic field frequency (f

Netz

= power frequency)

1

/

2

×

f

Netz

1

/

6

×

f

Netz

1

/

18

×

f

Netz

1

/

36

×

f

Netz

Select with

key.

Press

key to transfer to subfunction “Flow Direction”.

for DC devices to subfunction „Line Frequenz“

Line Frequenz

Normal line frequency in your country

This function is only provided for units with DC power supply

• 50 Hz • 60 Hz

Select with

key.

Press

key to transfer to subfunction “Flow Direction”.

Flow Direction

Define flow direction (in F/R mode: forward flow).

• + Direction

• - Direction

Select with

key.

Press

key to return to Fct. 3.02 “Flowmeter”.

3.03

Zero Point

Zero calibration

• return

(quit function without making change)

• calculate

(calculate new zero value)

Press

key to start, duration approx. 15-90 seconds.

Save new value, select with

key:

• save no

(do not save zero value)

• save yes

(save new zero value)

• change

(change zero value manually)

Press

key to transfer to unit selection:

m

3

/h • Liter/s • US Gal/min

• any unit, see Fct. 3.05 (factory setting: Liter/h)

Press

key to transfer to number setting.

Value may be max. 10% of Q

100%

Press

key to return to Fct. 3.03 “Zero Point”.

3.04

Entrycode

Entry code required to enter setting mode?

• NO (= entry with

only)

• YES(= entry with

and Code 1:

)

Press

key to return to Fct. 3.04 “Entrycode”.

3.05

User Units

Set any required unit for flowrate and counting

Text Volumen

Set text for required flowrate unit (max. 5 characters)

Factory-set: Liter or MGal .

Characters assignable to each place: • A-Z, a-z, 0-9, or — (= blank character)

Press

key to transfer to subfunction “Factor Volumen”.

Factor Volumen

Set conversion factor (FM) for volume

Factory set 1.00000 for Liter or 2.64172E-4 for US MGal

(exponent notation, here: 1x 10

3

or 2.64172x10

-4

).

Factor FM = volume per 1m

3

.

Setting range • 1.00000 E-9 to 9.99999 E+9 (= 10

-9

to 10

+9

)

Press

key to transfer to subfunction “Text Time”.

Text Time

Set text for required time unit (max. 5 characters)

Factory-set: hr.

Characters assignable to each place: • A-Z, a-z, 0-9, or — (= blank character)

Press

key to transfer to subfunction “Factor Time”.

Factor Time

Set conversion factor (F

T

) for time

Factory-set: 3.60000 E+3 for hour or 8.64000 E+4 for day

(exponent notation, here: 3.6 x10

3

or 8.64 x10

-4

).

Set factor FT in seconds.

Setting range • 1.00000 E-9 to 9.99999 E+9 (= 10

-9

to 10

+9

)

Press

key to return to Fct. 3.05 “User Units”.

3.06 Application

Set

application

conditions

Flow

Set characterization for flow

• Steady

(steady flow, max. 150% of Q

100%

)

• Pulsating

(pulsating flow, up to 1000% of Q

100%

e.g. caused by reciprocating pumps, refer to Sect. 6.4)

Press

key to transfer to subfunction “Empty Pipe”.

Empty Pipe

Signal when measuring tube is empty (refer to Sect. 6.3 )

• no • yes (possible only with built-in option)

Press

key to return to Fct. 3.06 “Application”.