beautypg.com

KROHNE IFC 210 E Short EN User Manual

Page 24

background image

Sect. 4.2

Part B IFC 210 Signal converter

24

IFC 210 E

05/2002

Fct.

Display-Texts

Description and settings

2.00

Test

Test menu

2.01

Test Q

Test measuring range Q

Precautionary query

• SURE NO

Press

key to return to Fct. 2.01 TEST Q .

• SURE YES

Press

key to transfer to number setting.

select value: -110 / -100 / -50 / -10 / 0 / +10 / +50 / +100 / +110 PCT..

of set full-scale range Q

100%

.

Displayed value present at outputs I and P.

Press

key to return to Fct. 2.01 “TEST Q” .

2.02

Hardwareinfo

Hardware information and error status

Before consulting factory, please note down all codes.

Modul

ADC

X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y

Modul

IO

X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y

Press

key to transfer to next info.

Modul

DISP.. X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y

Modul

RS

X . X X X X X . X X

(only provided if “computer interface”

Y Y Y Y Y Y Y Y Y Y

Option installed)

Press

key to return to Fct. 2.02 “Hardwareinfo”.

2.03

Test Display

Press

key to start test of display, duration approx. 5 sec.

Fct.

Display-Texts

Description and settings

3.00

Installation

Installation menu

3.01

Language

Select language for display texts

• GB / USA (English)

• F (French)

• D (German)

• others on request

Press

key to return to Fct. 3.01 “Language”.

3.02

Flowmeter

Set data for primary head

Diameter

Select size from meter size table

• DN 2.5 - 3000 mm equivalent to

1

/

10

– 120 inch

Select with

key.

Press

key to transfer to subfunction “Full Scale”.

Full Scale

Full-scale range for flow Q

100%

Selection unit: •

m

3

/hr

• Liter/Sec

• US Gal/min

user unit, factory set is Liter/hr or US MGal/day (see Fct. 3.05)

Press

key to transfer to number setting.

Setting ranges:

The ranges are dependent on the meter size (DN) and the

flow velocity (v):

Q

min

= DN

2

x v

min

Q

max

= DN

2

x v

max

Nom. dia. /meter size

V

min

= 0,3 m/s (1 ft/s) V

max

= 12 m/s (40 ft/s)

• DN 2.5–1600 /

1

/

10

– 64:

0.0053 –

86 859 m

3

/hr

0.0237 –

401 080 US Gal/min

Press

key to transfer to subfunction “Gk Value”.

Value P

Pulse value has been changed.

With the old pulse values the output frequency (F)

would have been exceeded or not reached.

P

min

= F

min

/ Q

100%

P

max

= F

max

/ Q

100%

Check new values!

Gk Value

Set primary constant GK

see primary head nameplate.

Range:

• 1.0000 - 9.9999

Press

key to transfer to subfunction “Field Frequenz”.