4.3 Error messages in
measuring mode
The following list gives all errors that can occur during process flow measurement.
Errors shown in display when “YES” set in Fct. 1.04 DISPLAY, subfunction “DISP. MSG.”
Error messages
Description of error
Error clearance
LINE INT.
Power failure
Note: no counting during power failure
Cancel error in RESET/QUIT. Menu
Reset totalizer if necessary.
CUR. OUTP. I
Current output overranged.
Check and if necessary correct
instrument parameters. After elimination
of cause, error message deleted
automatically.
PULSOUTP. P
Pulse output overranged.
Note: totalizer deviation possible.
Check and if necessary correct
instrument parameters. After elimination
of cause, error message deletes
automatically.
ADC
Analog / digital
converter overranged
Error message deletes automatically after
elimination of cause.
FATAL. ERROR
Fatal error, all outputs set to “min. values”
Please consult factory.
TOTALIZER
Totalizer has been reset
Cancel error message in
RESET/QUIT menu.
EMPTY PIPE
Pipe has run dry. Message appears only
when the “empty pipe identifier” option
is installed and the function is activated
under Fct. 3.06 APPLICAT., submenu
“EMPTY PIPE”.
Fill pipe.