beautypg.com

KROHNE IFC 010 Converter Short EN User Manual

Page 14

background image


14 IFC

010

Function Text

Description

and

settings

1.05

CURRENT I

Current output I

FUNCT. I

Select function for current output I

• OFF (switched off)

• 1 DIR. (1 flow direction)

• 2 DIR. (forward/reverse flow, F/R flow measurement)

RANGE I

Select measuring range

• 0 - 20 mA

• 4 - 20 mA (fixed ranges)

I ERROR

Select error value

• 0 mA

• 3.6 mA (only with range 4-20 mA)

• 22 mA

1.06

PULS.OUTP. P

Pulse output P

FUNCTION P

Select function for pulse output P

• OFF (switched off)

• 1 DIR. (1 flow direction)

• 2 DIR. (forward/reverse flow, F/R measurement)

SELECT P

Select pulse type

• 100 Hz

• PULSE/VOL. (pulses per unit volume, flow rate)

• 1000 Hz

• PULSE/TIME (pulses per unit time for 100% flowrate)

PULSWIDTH

Select pulse width

• 50 mSec • 100 mSec • 200 mSec

• 500 mSec • 1 Sec

VALUE P

Set pulse value per unit volume

(appears only when “PULSE/VOL.“ has been set under “SELECT P“)

• xxxx PulS/m

3

• xxxx PulS/Liter • xxxx PulS/US.Gal

• xxxx PulS/ user unit, factory set is “Liter“ or “US MGal“ (see Fct. 3.05).

VALUE P

Set pulse value per unit time

(appears only when „PULSE/TIME“ has been set under „SELECT P“).

• xxxx PulS/Sec (=Hz) • xxxx PulS/min • xxxx PulS/hr

• xxxx PulS/user unit, factory set is “hr” or “day” (see Fct. 3.05)

1.07

IND. OUTP. S

Status output S

• ALL ERROR • FATAL ERROR • OFF • ON

• F/R INDIC.

(F/R indication for forward/reverse measurement)

• TRIP. POINT Setting range: 002 - 115 PERCENT

• EMPTY PIPE (appears only when this option is installed)

2.00

TEST

Test

menu

2.01

TEST Q

Test measuring range Q

Precautionary query

• SURE NO

Press

key to return to Fct. 2.01 “TEST Q”.

• SURE YES

Press

key, then useorkey to select value:

-110 / -100 / -50 / -10 / 0 / +10 / +50 / +100 / +110 PCT.

2.02

HARDW. INFO

Hardware information and error status

Before consulting factory, please note down all 6 codes.

MODUL ADC

X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y

MODUL IO

X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y

MODUL DISP.

X . X X X X X . X X

Y Y Y Y Y Y Y Y Y Y