beautypg.com

Technical data – KROHNE OPTIWAVE 7300C Quickstart EN User Manual

Page 29

background image

TECHNICAL DATA

4

29

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000050005 - QS OPTIWAVE 7300 R08 en

FM – Dual Seal-approved

NEC 500

NEC 500

NEC 500

NEC 500

XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6-T1;

DIP / Cl. II, III / Div. 1 / Gr. EFG / T6-T1;

IS / Cl. I, II, III / Div. 1 / Gr. ABCDEFG / T6-T1;

NI / Cl. I / Div. 2 / Gr. ABCD / T6-T1

NEC 505

NEC 505

NEC 505

NEC 505

Cl. I / Zone 0 / AEx d[ia] / IIC / T6-T1;

Cl. I / Zone 0 / AEx ia / IIC / T6-T1;

Cl. I / Zone 2 / AEx nA[ia] / IIC / T6-T1

Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal

CSA – Dual Seal-approved

CEC Section 18 (Zone ratings)

CEC Section 18 (Zone ratings)

CEC Section 18 (Zone ratings)

CEC Section 18 (Zone ratings)

Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0) T6;

Cl. I, Zone 0, Ex ia, IIC T6;

Cl. I, Zone 2, Ex nA, IIC T6

CEC Section 18 and Annex J (Division ratings)

CEC Section 18 and Annex J (Division ratings)

CEC Section 18 and Annex J (Division ratings)

CEC Section 18 and Annex J (Division ratings)

XP-IS, Cl. I, Div. 2, Gr. ABCD; Cl. II, Div. 2, Gr. FG; Cl. III, Div. 2 T6;

IS, Cl. I, Div. 1, Gr. ABCD; Cl. II, Gr. FG; Cl. III T6

NEPSI

GYJ111193/94

Ex dia IIC T3~T6 DIP A21/A20 T

A

T70°C~T95°C IP6X;

Ex ia IIC T3~T6 DIP A21/A20 T

A

T70°C~T95°C IP6X

DNV / INMETRO

DNV 12.0043 X

Ex ia IIC T6…T3 Ga; Ex ia IIIC T70°C...T95°C Da IP6X;

Ex d [ia Ga] IIC T6...T3 Ga/Gb; Ex tb [ia Da] IIIC T70°C...T95°C Db IP6X

KGS

11-GA4BO-0324X

11-GA4BO-0329X

Ex ia IIC T6~T3; Ex iaD 20 IP6X T70°C~T95°C;

Ex d[ia] IIC T6~T3; Ex tD[iaD] A21/20 IP6X T70°C~T95°C

Other standards and approvals

Other standards and approvals

Other standards and approvals

Other standards and approvals

EMC

Electromagnetic Compatibility Directive 2004/108/EC in conjunction with

EN 61326-1 (2013)

R & TTE

Radio Equipment and Telecommunications Terminal Equipment Directive

1999/5/EC in conjunction with ESTI EN 302 372-1 (2011) and EN 302 372-2 (2011)

FCC Rules

Part 15

Industry Canada

RSS-210

LVD

Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001)

NAMUR

NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and

Laboratory Control Equipment

NAMUR NE 43 Standardization of the Signal Level for the Failure Information of

Digital Transmitters

WHG

Z-65.16-425

In conformity with the German Federal Water Act, §9

CRN

This certification is for all Canadian provinces and territories. For more data, refer

to the website.

Construction code

Option: NACE MR0175 / NACE MR0103 / ISO 15156

1 The device has a distance piece if it has the flange options that follow: DN100 PN100, DN150 PN63 or PN100, DN200 PN40, 6¨ in 300 lb,

3¨...4¨ in 600 lb, 3¨...4¨ in 900 lb, and 1½¨...2¨ in 900 lb or 1500 lb

2 This option is not available for FM- or CSA-approved devices
3 Hastelloy® is a registered trademark of Haynes International, Inc.
4 Tri-Clamp® is a registered trademark of Ladish Co., Inc. BioControl® is a registered trademark of Neumo-Ehrenberg-Group.
5 Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.
6 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG
7 HART® is a registered trademark of the HART Communication Foundation