INSTALLATION

2

13

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000050005 - QS OPTIWAVE 7300 R08 en

2.8.2 Standpipes (stilling wells and bypass chambers)

Use a standpipe if:

• There is highly conductive foam in the tank.
• The liquid is very turbulent or agitated.
• There are too many other objects in the tank.
• The device is measuring a liquid (petro-chemicals) in a tank with a floating roof.
• The device is installed in a horizontal cylindrical tank

For more data, refer to the Handbook.

2.9 How to install the device on the tank

2.9.1 How to install a device with a flange connection

Equipment needed:

• Device
• Gasket (not supplied)
• Nuts and bolts (not supplied)
• Wrench (not supplied)

Figure 2-14: Installation recommendations for standpipes (stilling wells and bypass chambers)

1 A stilling well solution
2 A bypass chamber solution
3 Air circulation hole
4 Level of the liquid