beautypg.com

Technical data – KROHNE OPTIWAVE 7300C Quickstart EN User Manual

Page 26

background image

4

TECHNICAL DATA

26

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000050005 - QS OPTIWAVE 7300 R08 en

Measuring accuracy

Resolution

1 mm / 0.04¨

Repeatability

±1 mm / ±0.04¨

Accuracy

±3 mm / ±0.12¨, when distance < 10 m / 33 ft;

±0.03% of measured distance, when distance > 10 m / 33 ft

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Temperature

+20°C ±5°C / +70°F ±10°F

Pressure

1013 mbara ±20 mbar / 14.69 psia ±0.29 psi

Relative air humidity

60% ±15%

Target

Metal plate in an anechoic chamber

Operating conditions

Temperature

Temperature

Temperature

Temperature

Ambient temperature

-40…+80°C / -40…+175°F (according to the temperature limits of the gasket

material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Storage temperature

-40…+85°C / -40…+185°F

Process connection temperature

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Standard: -50…+150°C / -58…+300°F

Option: -50…+200°C / -58…+390°F

(the process connection temperature must agree with the temperature limits of the

gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

-50…+150°C / -58…+300°F (the process connection temperature must agree with

the temperature limits of the gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

-40…+100°C / -40…+210°F (the process connection temperature must agree with

the temperature limits of the gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

-20…+150°C / -4…+300°F (the process connection temperature must agree with

the temperature limits of the gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Pressure

Pressure

Pressure

Pressure

Operating pressure

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

-1…16 barg / -14.5…232 psig;

subject to process connection used and flange temperature

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

-1…40 barg / -14.5…580 psig;

subject to process connection used and flange temperature

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

Hygienic antenna (PEEK):

-1…10 barg / -14.5…145 psig;

subject to process connection used and flange temperature

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Standard: -1…40 barg / -14.5…580 psig;

Option: -1…100 barg / -14.5…1450 psig;

subject to process connection used and flange temperature

Other conditions

Other conditions

Other conditions

Other conditions

Dielectric constant (ε

r

)

≥1.5

Vibration resistance

IEC 60068-2-6 and EN 50178 (10...57 Hz: 0.075 mm / 57...150 Hz:1g)

Ingress protection

IP 66/67 equivalent to NEMA type 4X (housing) and type 6P (antenna)