Supplementary Installation and Operating Instructions IFC 300 HART

HC275, FC375, AMS, PDM, FDT DTM


Attachment A

1 dynamic

variables

2 quick setup

3 test

4 setup

1 measured values

2 in/outputs

1 volume föw
2 mass flow
3 flow speed
4 conductivity
5 coil temperature
6 counter 1

Opt

7 counter 2

Opt

IFC 300 HART Menu Tree HC275 / FC375

1 language
2 tag
3 reset errors
4 unit A/C

Cust

5 range A/C min

Cust

6 range A/C max

Cust

7 time constant A/C

Cust

8 lfc threshold A/C

Cust

9 lfc hysteresis A/C

Cust

7 pulse val. unit

Opt, Cust

8 pulse value D

Opt, Cust

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local HC275/FC375,

affects only HC275/FC375 views

1 zero calibration

Cust

2 zero set

Cust

3 size

Cust

4 GK selection

Cust

5 GK / GKH

Opt, Cust

6 GKL

Opt, Cust

7 coil resist. Rsp

Cust

8 density

Cust

9 target conductivity

Cust

10 EF electr. factor

Cust

11 num. of electrodes
12 field frequency

Cust

13 select settling

Cust

14 settling time

Opt, Cust

15 line frequency

Cust

1 volume flow

2 mass flow

3 flow speed

4 conductivity

5 coil temperature

1 upper snsr limit

Rd

2 lower snsr limit

Rd

3 minimum span

Rd

2

1 calibration

2 filter

3 self test

4 information

5 sensor limits

1 simul. current/frequency A

Opt

2 simul. current/frequency B

Opt

3 simul. current C

Opt

4 simul. frequency D

Opt

1 process input

2 I/O

3 communication

4 device

1 limitation min

Cust

2 limitation max

Cust

3 flow direction

Cust

4 time constant
5 pulse filter

Cust

6 pulse width

Opt, Cust

7 pulse limitation

Opt, Cust

8 noise filter

Cust

9 noise level

Opt, Cust

10 n. suppression

Opt, Cust

11 lfc threshold

Cust

12 lfc hysteresis

Cust

1 A

Opt

2 % range A

Opt

3 B

Opt

4 % range B

Opt

5 C

Opt

6 % range C

Opt

7 D

Opt

8 % range D

Opt

3

1 empty pipe

Cust

2 limit empty pipe

Opt, Cust

3 full pipe

Opt, Cust

4 limit full pipe

Opt, Cust

5 linearity

Cust

6 gain

Cust

7 coil current

Cust

8 flow profile

Cust

9 limit flow profile

Opt, Cust

10 electrode noise

Cust

11 limit elect. noise

Opt, Cust

12 settling of field

Cust

1 liner
2 electrode material

KROHNE IFC 300 HA 45e30102 (1/3)