Supplementary Installation and Operating Instructions IFC 300 HART

HC275, FC375, AMS, PDM, FDT DTM


identification

operation unit

device

-----------------------------------

input

calibration

filter

self test

information

measuring limits

-----------------------------------

IO

A

Opt

B

Opt

C

Opt

D

Opt

counter 1

counter 2

-----------------------------------

human interface

local display

units (device)

units (HART)

formats (HART)

IFC 300 HART Menu Tree PDM

Parameter Table

4

4

output
• terminals A

Cust

• terminals B

Cust

• terminals C

Cust

• terminals D

Cust

human interface

units (HART)
• volume flow
• mass flow
• flow speed
• conductivity
• temperature
• counter 1
• counter 2

local display
• language
• default display

Cust

units (device)
• volume flow

Cust

• mass flow

Cust

• flow speed
• conductivity
• temperature
• volume

Cust

• mass

Cust

• density

Cust

formats (HART)
• volume flow

Loc

• mass flow

Loc

• flow speed

Loc

• conductivity

Loc

• temperature

Loc

• counter 1

Loc

• counter 2

Loc

A/B/C/D

Opt

...
status output

Opt

:

• mode
• output A

Opt

• output B

Opt

• output C

Opt

• output D

Opt

• invert signal

limit switch

Opt

:

• measurement
• threshold
• hysteresis
• polarity
• time constant
• invert signal

control input

Opt

:

• mode

Cust

• invert signal

current output

Opt

:

• range 0%

Cust

• range 100%

Cust

• ext. range min

Cust

• ext. range max

Cust

• error current

Cust

• error condition

Cust

• measurement

Cust

• range min

Cust

• range max

Cust

• polarity

Cust

• limit min

Cust

• limit max

Cust

• lfc threshold

Cust

• lfc hysteresis

Cust

• time constant

Cust

• special function

Cust

• rc threshold

Opt, Cust

• rc hysteresis

Opt, Cust

frequency output

Opt

:

• pulse shape

Cust

• pulse width

Cust

• 100% pulse rate

Cust

• measurement

Cust

• range min

Cust

• range max

Cust

• polarity

Cust

• limit min

Cust

• limit max

Cust

• lfc threshold

Cust

• lfc hysteresis

Cust

• time constant
• invert signal

Cust

• special function

Opt, Cust

• phase shift wrt. B

Opt, Cust

pulse output

Opt

:

• pulse shape

Cust

• pulse width

Cust

• max pulse rate

Cust

• measurement

Cust

• pulse value unit

Cust

• value p. pulse

Cust

• polarity

Cust

• lfc threshold

Cust

• lfc hysteresis

Cust

• time constant
• invert signal

Cust

• special function

Opt, Cust

• phase shift wrt. B

Opt, Cust

...

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local PDM, affects only PDM views

KROHNE IFC 300 HA 45e30102 (5/5)