Supplementary Installation and Operating Instructions IFC 300 HART

HC275, FC375, AMS, PDM, FDT DTM


Configure

Compare

Clear Offline

-----------------------------------

Status/Conditions

Process Variables

Scan Device

-----------------------------------

Calibration Management

Diagnostics and Test

Calibrate

Reset

-----------------------------------

Rename

Unassign

Assign / Replace

-----------------------------------

Audit Trail

Record Manual Event

Drawings / Notes ...

Help ...

Overview

Standard:
• Primary variable out of

limits

• Non-primary variable out

of limits

• Primary variable analog

output saturated

• Primary variable analog

output fixed

• Cold start
• Configuration changed
• Field device malfunction

Failure in device

• error in device
• IO1
• parameter
• IO2
• configuration
• display
• sensor electronic
• sensor global
• sensor local

IFC 300 HART Menu Tree AMS

Uncertain

• uncertain measurement
• pipe not full
• empty pipe
• linearity
• flow profile
• electrode noise
• gain error
• electrode symmetry

Application error

• application error
• empty pipe
• flow rate too high
• field frequency too high
• DC offset
• open circuit A
• open circuit B
• open circuit C

Check req. & Information

check request:
• checks in progress
• test sensor

information:
• counter 1 stopped
• counter 2 stopped
• power fail
• control input A active
• control input B active
• over range display 1
• over range display 2
• backplane sensor
• backplane settings
• backplane difference
• optical interface

1,2,3

5

• over range A (current)
• over range B (current)
• over range C (current)
• over range A (pulse)
• over range B (pulse)
• over range D (pulse)
• active settings
• factory settings
• backup 1 settings
• backup 2 settings

• field current local
• current output A
• current output B
• current output C
• software user interface
• hardware settings
• hardware detection
• RAM/ROM error IO 1
• RAM/ROM error IO 2

• field coil broken
• field coil bridged
• field current deviation
• field frequency too high
• electronic temperature
• coil temperature
• overflow counter 1
• overflow counter 2
• backplane invalid

5

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local AMS, affects only AMS views

KROHNE IFC 300 HA 45e30102 (4/5)