Ifc 300 hart menu tree ams – KROHNE IFC 300 Converter HART 0102 User Manual
Page 14
Supplementary Installation and Operating Instructions IFC 300 HART
HC275, FC375, AMS, PDM, FDT DTM
Configure
Compare
Clear Offline
-----------------------------------
Status/Conditions
Process Variables
Scan Device
-----------------------------------
Calibration Management
Diagnostics and Test
Calibrate
Reset
-----------------------------------
Rename
Unassign
Assign / Replace
-----------------------------------
Audit Trail
Record Manual Event
Drawings / Notes ...
Help ...
Overview
Standard:
• Primary variable out of
limits
• Non-primary variable out
of limits
• Primary variable analog
output saturated
• Primary variable analog
output fixed
• Cold start
• Configuration changed
• Field device malfunction
Failure in device
• error in device
• IO1
• parameter
• IO2
• configuration
• display
• sensor electronic
• sensor global
• sensor local
IFC 300 HART Menu Tree AMS
Uncertain
• uncertain measurement
• pipe not full
• empty pipe
• linearity
• flow profile
• electrode noise
• gain error
• electrode symmetry
Application error
• application error
• empty pipe
• flow rate too high
• field frequency too high
• DC offset
• open circuit A
• open circuit B
• open circuit C
Check req. & Information
check request:
• checks in progress
• test sensor
information:
• counter 1 stopped
• counter 2 stopped
• power fail
• control input A active
• control input B active
• over range display 1
• over range display 2
• backplane sensor
• backplane settings
• backplane difference
• optical interface
1,2,3
5
• over range A (current)
• over range B (current)
• over range C (current)
• over range A (pulse)
• over range B (pulse)
• over range D (pulse)
• active settings
• factory settings
• backup 1 settings
• backup 2 settings
• field current local
• current output A
• current output B
• current output C
• software user interface
• hardware settings
• hardware detection
• RAM/ROM error IO 1
• RAM/ROM error IO 2
• field coil broken
• field coil bridged
• field current deviation
• field frequency too high
• electronic temperature
• coil temperature
• overflow counter 1
• overflow counter 2
• backplane invalid
5
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Cust
Custody Lock protected
Loc
Local AMS, affects only AMS views
KROHNE IFC 300 HA 45e30102 (4/5)