Ifc 300 hart menu tree pdm menu bar – KROHNE IFC 300 Converter HART 0102 User Manual
Page 18
Supplementary Installation and Operating Instructions IFC 300 HART
HC275, FC375, AMS, PDM, FDT DTM
File
Device
View
Options
Help
Display
Yt Diagram
Outputs
Device Status
Circuit Board Info
-----------------------------------
Toolbar
Status Bar
-----------------------------------
Update
1
IFC 300 HART Menu Tree PDM
Menu Bar
device
• C number
HART:
• tag
• manufacturer
Rd
• model
Rd
• device ID
Rd
standard
overview:
• Primary variable out of limits
• Non-primary variable out of limits
• AO outside the operating range limits
• Analog Output in fixed mode
• Cold start
• Configuration changed
• Field device malfunction
application error:
• application error
• empty pipe
• flow rate too high
• field frequency too high
• DC offset
• open circuit A/B/C
• over range A/B/C (current)
• over range A/B/D (pulse)
• active settings
• factory settings
• backup 1/2 settings
failure / application
failure in device:
• error in device
• IO1
• parameter
• IO2
• configuration
• display
• sensor electronic
• sensor global
uncertain / checks / info
uncertain:
• uncertain measurement
• pipe not full
• empty pipe
• linearity
• flow profile
• electrode noise
• gain error
• electrode symmetry
• field coil broken
• field coil bridged
• field current deviation
information:
• counter 1 stopped
• counter 2 stopped
• power fail
• control input A active
• control input B active
• over range display 1
• over range display 2
• backplane sensor
• backplane settings
• backplane difference
• optical interface
3
failure in device:
• sensor local
• field current local
• current output A
• current output B
• current output C
• software user interface
• hardware settings
• hardware detection
• RAM/ROM error IO 1
• RAM/ROM error IO 2
• universal revision
Rd
• device revision
Rd
• software revision
Rd
• hardware revision
Rd
• date
Rd
• write protect
Rd
• final assembly no.
Rd
• sensor serial no.
Rd
• field frequency too high
• electronic temperature
• coil temperature
• overflow counter 1
• overflow counter 2
• backplane invalid
check request:
• checks in progress
• test sensor
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Cust
Custody Lock protected
Loc
Local PDM, affects only PDM views
KROHNE IFC 300 HA 45e30102 (3/5)