Ifc 300 hart menu tree pdm menu bar – KROHNE IFC 300 Converter HART 0102 User Manual

Page 18

background image

Supplementary Installation and Operating Instructions IFC 300 HART

HC275, FC375, AMS, PDM, FDT DTM


File

Device

View

Options

Help

Display

Yt Diagram

Outputs

Device Status

Circuit Board Info

-----------------------------------
Toolbar
Status Bar
-----------------------------------
Update

1

IFC 300 HART Menu Tree PDM

Menu Bar

device
• C number

HART:
• tag
• manufacturer

Rd

• model

Rd

• device ID

Rd

standard
overview:
• Primary variable out of limits
• Non-primary variable out of limits
• AO outside the operating range limits
• Analog Output in fixed mode
• Cold start
• Configuration changed
• Field device malfunction

application error:
• application error
• empty pipe
• flow rate too high
• field frequency too high
• DC offset
• open circuit A/B/C
• over range A/B/C (current)
• over range A/B/D (pulse)
• active settings
• factory settings
• backup 1/2 settings

failure / application
failure in device:
• error in device
• IO1
• parameter
• IO2
• configuration
• display
• sensor electronic
• sensor global

uncertain / checks / info
uncertain:
• uncertain measurement
• pipe not full
• empty pipe
• linearity
• flow profile
• electrode noise
• gain error
• electrode symmetry
• field coil broken
• field coil bridged
• field current deviation

information:
• counter 1 stopped
• counter 2 stopped
• power fail
• control input A active
• control input B active
• over range display 1
• over range display 2
• backplane sensor
• backplane settings
• backplane difference
• optical interface

3

failure in device:
• sensor local
• field current local
• current output A
• current output B
• current output C
• software user interface
• hardware settings
• hardware detection
• RAM/ROM error IO 1
• RAM/ROM error IO 2

• universal revision

Rd

• device revision

Rd

• software revision

Rd

• hardware revision

Rd

• date

Rd

• write protect

Rd

• final assembly no.

Rd

• sensor serial no.

Rd

• field frequency too high
• electronic temperature
• coil temperature
• overflow counter 1
• overflow counter 2
• backplane invalid

check request:
• checks in progress
• test sensor

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local PDM, affects only PDM views

KROHNE IFC 300 HA 45e30102 (3/5)