RTW 300W 101212

5

FIGURE 2. POWER RATING VS. TEMPERATURE

FIGURE 3. MOUNTING POSITIONS FOR THE RTW 300W POWER SUPPLY

4.

OPERATION

Figure 4 shows the location of all operating controls and input/output terminals followed by an
explanation of each. The unit is shipped with a shorting connector installed connecting: +RC to
–RC and local sensing cables connecting +DC Output with +S and –DC Output with –S for local
sensing.

NOTES:

a. +S and –S MUST be properly connected for the unit to operate. For local sens-

ing, leave local sensing cables in place (refer to PAR. 6.1). For remote sensing
(at the load), refer to PAR. 6.2.

b. If remote ON/OFF is not being used, ±RC pins of either connector CN2 or CN3

must be connected (use shorting connector supplied) for unit to operate.