1. DESCRIPTION
Kepco Kit 219-0532 provides a low-noise cable and scope probe adapter used to measure ripple and noise, respec-
tively, of ABC Series power supplies. The guidelines provided in this instructions sheet supplement the procedures
found in the ABC Service Manual for Ripple Measurement and Noise Measurement. These guidelines help the user to
replicate the methods used by Kepco to measure ripple and noise of ABC power supplies. This procedure should only
be performed after the unit has been fully calibrated and passed all other performance tests specified in the applicable
ABC Service Manual.
2. MATERIAL REQUIRED (SEE TABLE 1.)
TABLE 1. MATERIAL REQUIRED
MATERIAL
KEPCO
PART NUMBER
LOCATION
QUANTITY
• Ripple Measurement Cable
25422
Provided in this Kit
1
• Noise Measurement Scope Probe Adapter
25423
Provided in this Kit
1
• 60MHz Oscilloscope, Tektronix 2215A
1
n/a
Not supplied
1
• Tektronix Passive Probe Model P6109B (10X
100MHz)
1
n/a
Not supplied
1
• Instruction Sheet
228-1642
Provided in this Kit
1
1. Kepco strongly recommends using the models specified to ensure measurements are equivalent to those made at the
factory. The user is encouraged to contact Kepco Applications Engineeringfor guidance on the use of equivalents.
Document Outline
- 1. Description
- 2. MATERIAL REQUIRED (See TABLE 1.)
- TABLE 1. Material ReQuired
- 3. Measurement Guidelines
- TABLE 2. Ripple and Noise Specifications
- FIGURE 1. ABC 10-10DM Measurement Data
- FIGURE 2. ABC 15-7DM Measurement Data
- FIGURE 3. ABC 25-4DM Measurement Data
- FIGURE 4. ABC 36-3DM Measurement Data
- FIGURE 5. ABC 60-2DM Measurement Data
- FIGURE 6. ABC 125-1DM Measurement Data