3 specifications – Detcon P-1000 User Manual
Page 8

P-1000
Portable Model 1000 H2S Analyzer
Rev. 1.0
Page 4 of 24
Gas Name
Symbol
Cross
Gas Name
Symbol
Cross
Ammonia NH3
n/d
Hydrogen Cyanide
HCN
10=0
Arsenic Triflouride
AsF3
n/d
Hydrogen Flouride
HF
n/d
Arsenic Pentaflouride
AsF5
n/d
Hydrogen Selenide
HSe
n/d
Arsine AsH3
n/d
Iodine I2
n/d
Boron Triflouride
BF3
n/d
Isopropanol C3H8O
n/d
Bromine Br2
n/d
Methane CH4
n/d
Butadiene C4H6
n/d
Methanol CH3OH
n/d
Buten-1 Buten-1
n/d
Methyl-ethyl-ketone C4H8O n/d
Carbon Dioxide
CO2
n/d
Methyl Mercaptan
CH3SH
2:1
Carbon Disulfide
CS2
n/d
Nitric Oxide
NO
35=<2
Carbon Oxide Sulfide
COS
n/d
Nitrogen N2
n/d
Carbon Monoxide
CO
300-1.5
Nitrogen Dioxide NO2 5=-0.5
Carbonyl Sulfide
COS
n/d
Oxygen O2
n/d
Chlorine
CL2
1§0.2
Ozone O3
n/d
Chlorine Dioxide
CLO2
n/d
Phosgene COCL2
n/d
Chlorine Triflouride
CLF3
n/d
Phosphine PH3
n/d
Diborane B2H6
n/d
Phosphorous Triflouride
PF3
n/d
Dimethyl Sulfide
C2H6S
n/d
Silane SiH4
n/d
Disilane Si2H6
n/d
Silicon Si
n/d
Epichlorohydrin C3H5OCL
n/d
Silicon Tetra Flouride
SiF4
n/d
Ethanol C2H5OH
n/d
Sulfur Dioxide
SO2
5=<1
Ethyl Mercaptan
C2H5SH
3=1
Tetrahydrothiophene C4H8S n/d
Ethylene C2H4
100=0
Thiophane C4H4S
n/d
Ethylene Oxide
C2H4O
n/d
Toluene C6H5CH3
n/d
Fluorine F2
n/d
Tungsten Hexaflouride
WF6
n/d
Formaldehyde CH2O
n/d
Vinyl Acetate
C4H6O2
n/d
Germane GeH4
n/d
Vinyl Chloride
C2H3CL
n/d
Hydrazine N2H4
n/d
Mercaptan compounds are the most commonly found cross interference gases found in natural gas samples.
High alcohol concentrations should not effect readings except as transients during rapid concentration changes.
1.3 Specifications
Method of Detection
Electrochemical Cell
Accuracy/Repeatability
± 2% FS
Output
Linear 4-20mA DC
Operating Temperature
-40 to 75°C
Operating Pressure
Inlet 5-10psig; Outlet Vent: Ambient ±1psig
Power Consumption
Normal operation = 4mA (0.1 watts @ 12VDC); Maximum = 20mA (0.5 watts @ 12VDC)
Electrical Classification
General Purpose NEMA4X