beautypg.com

0 specifications – Detcon 10C Facilities User Manual

Page 15

background image

Model 10C

10C Control Module Instruction Manual Rev. 0.0

Page 11 of 14

6.0 Specifications

Input Power

9VDC to 28VDC, 100mA maximum (TBD)

Operating Temperature

-40deg to +70degC

Humidity:

10 to 95% Non-condensing

Inputs/Outputs:

Channel 1 Serial Communications RS485 Modbus

Channel 2 Serial Communications RS485 Modbus

Relays
Relay Contact Terminations:

Common, Normally Open, and Normally Closed

Three Relays on board

Relay Contact

Specification per Manufacturer:

Resistive Load:

5A, 250VAC; 2A, 30VDC

Inductive Load:

2A, 250VAC; 2A, 30VDC

Maximum Operating Current:

5A


Alarm/Fault Alarm Timing:

Alarms are reported to relays and LED annunciators as soon as they
appear over Modbus from the Slave SSCs. Report time for all
Mod10C slaves is about 32 Slaves per second.

Warranty:

One year.

Five year fixed fee service policy.