Functional block diagram functional block diagram, Output response curve – Detcon IR-542 User Manual
Page 6
3.2 A
PPLICATION
Model IR-540/IR-541/IR-542 MicroSafe™ sensors are designed to detect and monitor CO2 gas in ambient air.
Minimum sensitivity and scale resolution is 0.01%. Operating temperature range is -40° F. to +175° F. While the sensor
is capable of operating outside these temperatures, performance specifications are verified within the limit.
3.2.1 Sensor Placement/Mounting
Sensor location should be reviewed by facility engineering and safety personnel.
3.3 S
PECIFICATIONS
Method of Detection
NDIR Optical
Electrical Classification
Class I; Groups B, C, D; Div. 1.
Detcon Model IR-540/IR-542 Carbon Dioxide Sensor PG.6
Functional
Block
Diagram
Functional
Block
Diagram
4-20 mA Out
Power In
Pre-Amp
Display
4-20mA
Micro-
processor
Transmitter
Power Supply
Optical
Sensor
I/O Circuit
Protection
Temperature
Compensation
0
4
8
12
16
20
20
40
60
80
100
% of Range of Detection
m
A
D
C
S
ig
n
a
l
O
u
tp
u
t