Page 6 of 48

There are some gases typically found in industrial environments that can cause a cross-interference response
on the sensor. See the Table below for some examples.

Table 1 Cross Interference Gases

GAS

PPM

GAS

PPM

Methane

25,000 = 0

Ammonia

500 = 1

Ethane

5,000 = 0

Diesel Fuel

1000 = 0

Hexane

5,000 = 0

Dimethyl Sulfide

4.4 = 0

Propane

5,000 = 0

Ethylene

200 = 0

Butane

5,000 = 0

Freon 12

1,000 = 0

Carbon Monoxide

1% = 0

Hydrogen

5% = 0

Carbon Dioxide

5,000 = 0

Methyl Mercaptan

10 = 0

Carbon Disulfide

14 = 0

Sulfur Dioxide

300 = 0

Methanol

500 = 5

Toluene

32 = 0

Isopropanol

500 = 3

Ethanol

500 = 5

NOTE: The Detcon MOS Sensor Cell can be damaged to the point of non-functioning if the
unit is left off power and in the presence normal air levels of moisture for periods exceeding 8
hours.

NOTE: Always protect the sensor cell with the Detcon Sealing Cap and a fresh desiccant
packet when the sensor is powered off, this will avoid permanent sensor cell damage and help
preserve the span calibration.

2.4 Mounting Installation

The TP-524D-HRT should be vertically oriented so that the sensor points straight downward. The explosion-
proof enclosure or junction box would then typically be mounted on a wall or pole (See Figure 6). Detcon
provides a selection of standard junction boxes in both Aluminum and Stainless Steel.

NOTE: Do not use Teflon Tape or any other type of Pipe Thread material on the ¾” threads
unless the unit is mounted in a severe or harsh environment. Metal-on-metal contact must be
maintained to provide a solid electrical ground path. If Teflon Tape is used the Sensor must be
externally grounded using a ground strap.

When mounting on a pole, secure the Junction Box to a suitable mounting plate and attach the mounting plate
to the pole using U-Bolts. (Pole-Mounting brackets for Detcon Junction Box’s are available separately.)