Delmhorst Instrument Moisture Check User Manual
Page 8
Copyright
2005, Delmhorst Instrument Co.
Page 8 of 29
3. Use the
ò key to highlight the default material (Douglas Fir) if you wish to change it
to a different material. Press the SELECT key to get into the SELECT MATERIAL sub
menu.
4. Use the
с т keys to highlight the material you are testing. Press the SELECT key to
choose that material. This will bring you back to the main %MC READ screen.
5. Use the
п р keys to highlight the pin type selection. Press the SELECT key to
toggle between 4-pin (non-insulated) pins and 2-pin (insulated) pins.
You may begin taking readings by inserting the pins into the material and pressing the
SELECT key. This will display a %MC reading. If you wish to hold a reading on screen,
press the SELECT key again; otherwise remove the pins from the material being tested
and take another reading.
TO SET THE ALARM IN BASIC PIN MODE:
1. If you wish to set the alarm to beep after a pre-selected %MC value is reached, use the
с т keys from the %MC screen to highlight the ALARM. Press the SELECT key to
enter the alarm sub menu.
2. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.
3.
After the alarm is turned on, use the
п р keys to scroll up or down to a higher or
lower alarm value.
4. After you have selected the alarm value, use the
ò key to highlight DONE. Press
SELECT to get back to the %MC READ screen.