Avigilon Control Center 5 System Integration Guide with STENTOFON AlphaCom

7

1.

In the Configure Connections dialog box, enter the AlphaCom XE Exchange IP
address and port number.

2.

Click Connect to link the Avigilon Control Center and AlphaCom software with
the integration. A popup message appears to notified you that the connection
is successful.

3.

Click Done. The Configuration Tool window is displayed.

Mapping Alarms

In the Configuration Tool is a list of all the current alarm mappings, and all the available
alarms from the Avigilon Control Center software and the AlphaCom software.

If the Configuration Tool is not already open, select All Programs > Avigilon > Avigilon
AMAG SMS Gateway > Configure Avigilon to AMAG SMS Gateway
.

To map alarms together, complete the following steps:

1.

In the Trigger Conditions area, enter the trigger conditions that were
configured in the AlphaCom XE exchange.

Digit refers to the string used to identify the OnCustomParameter event, and
Node refers to the AlphaCom XE exchange this OnCustomParameter event is