beautypg.com

Installation, Important – Van Air Systems FR-1600 User Manual

Page 21

background image

PAGE 3

INSTALLATION

FIGURE 1A BYPASS

INLET

SHUTOFF

VALVE

BYPASS

VALVE

FILTER

OUTLET

SHUTOFF

VALVE

FIGURE 1C FILTERS MANIFOLDED WITH CONNECTOR KIT

COALESC-

ING FILTER

(HIGHER EF-

FICIENCY)

PARTICULATE

FILTER

(LOWER EF-

FICIENCY)

FIGURE 1B FILTERED BYPASS

INLET

SHUTOFF

VALVE

OUTLET

SHUTOFF

VALVE

FILTER

INLET

BYPASS

VALVE

OUTLET

BYPASS

VALVE

BYPASS

FILTER

Before installing filter, check operating temperature and pres-

sure conditions to verify that they are within the specified

ranges.

(See Operating Conditions on page 1). Also verify

that system flow rate corresponds to the rated capacity of

the filter. Operating at flows above rated capacity will result

in increased pressure drop.

Locate Filter at the point of lowest operating temperature to

ensure that water and oil vapor do not condense downstream

of the filter. Filter should be installed close to the point of

use to minimize the risk of pipe scale, dirt, etc. recontaminat-

ing the compressed air. This is particularly important when

installing a new filter on an existing system that has not had

proper filtration.

Install filter vertically. Provide required minimum clearance

below filter to allow for replacement of element.

(See Element Removal Clearance on page 2).

Protect filter from reverse flow conditions. Do not install filter

downstream of quick opening valves.

Remove filter head from the bowl by turning bowl counter-

clockwise. Pull element from locator. Set bowl and element

aside for use later.

Install inlet and outlet shutoff valves to facilitate replacement

of element. Bypass piping is recommended

(See Figure 1A

and 1B). MAKE SURE VALVES ARE CLOSED BEFORE

PROCEEDING.

Connect filter head into piping. Avoid reducers or bushings to

match inlet size. The resulting restriction will increase pressure

drop. Make sure head is installed with flow arrows pointing

in proper direction. Use pipe thread compound as required.

1.

2.

3.

4.

5.

6.

7.

IMPORTANT

INSTALL FILTER HEAD INTO THE PIPING WITH AR-

ROWS POINTING IN THE PROPER DIRECTION TO

ENSURE PROPER OPERATION. (SEE FLOW DIREC-

TION DIAGRAM BELOW).

Install element by pushing onto element locator on filter head.

Check to make sure that the o-ring in the head is in the proper

position. Thread filter bowl into filter head and tighten either

by hand (models F200-15 through 55) or with strap wrench

(models F200-85 through 1250). Do not over tighten. Overtight-

ening could damage filter bowl or make it difficult to remove.

Make sure drain valve on bottom of filter is closed. On filters

equipped with ADM2-2 auto drain, provide a drain line to

remove accumulated water and oil.

Pressurize system and slowly open inlet and outlet shutoff

valves.

Check piping for leaks. Depressurize system and repair leaks

as needed.

Re-pressurize system and slowly open inlet and outlet shutoff

valves. Close bypass valve if provided.

Filter is now in service.

8.

9.

10.

11.

12.

13.

14.