beautypg.com

Triton RL2000 User Manual User Manual

Page 91

background image

116

Motor Fault

1. Inspect for jammed currency in the feed path and at the Exit
sensor. Remove any jammed currency.
2. Purge the dispenser using the purge command. Test the
dispensing mechanism by completing several Test Dispenses.
3. If the error clears put the Cash Dispenser into service.
Otherwise, replace the dispensing mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

117

Timeout waiting for note to divert

118

Exit sensor blocked on start of
dispense or learn

1. Inspect for jammed currency at the Exit. Remove jammed
currency.
2. Verify that all access panels are closed and secured.
3. Use a soft brush and vacuum cleaner to clean the exit sensor.
4. Clear the error. Test the dispenser by completing several test
dispenses.
5. If the error clears, put the cash dispenser in service.
6. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

119

Diverter in dispense position on
start of dispense or learn

1. Inspect for jammed currency at the Diverter. Remove jammed
currency.
2. Check the operation of the diverter solenoid.
3. Verify that all access panels are closed and secured. Clear the
error. Test the dispenser by completing several test dispenses.
4. If the error clears, put the cash dispenser in service.
5. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

121

Note cassette not present

122

Unexpected note at exit

1. Purge the dispenser using the purge command from diagnostic
menu.
2. Test the dispenser by completing several test dispenses. If the
error clears, put the cash dispenser in service.
3. If these actions have no effect on dispenser operation, replace
the dispenser mechanism and/or the note cassette.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

123

Hardware Error

1. Purge the dispenser using the purge command from diagnostic
menu.
2. Test the dispenser by completing several test dispenses. If the
error clears, put the cash dispenser in service.
3. If these actions have no effect on dispenser operation, print a
dispenser status report, scan the click count history, starting at the
bottom. Find the first occurrence of “116”. The next entry, below
116 is the Hardware Status. Look up the definition on the Hardware
Status listing.
4. If problems still persist, replace the dispenser mechanism and/or
the note cassette.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

124

Diverter moved to exit position
during reject purge

1. Inspect for a currency jam at the diverter.
2. Verify that the diverter moves freely.
3. Test the dispenser by completing several test dispenses.
4. If the error clears, put the cash dispenser in service.
5. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support