SPED - Enable JETCO PIN entry mode
failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
586
SPED - Enable JETCO PIN entry mode
failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
587
NMD 50 required Cassette in TOP
hopper
588
ERR PRESENTER OFFLINE
Verify that a cable from the docking board to the presenter controller board is
securely connected at both ends. If the cable appears undamaged, and it is
securely connected at the docking board and the presenter controller board,
replace the presenter assembly. If replacing the presenter does not clear the
error, other possible causes of this problem may be the main board assembly
or the docking board.
589
ERR PRESENTER MOTOR STALLED Inspect the gears assembly on the presenter for possible damage. Replace
the presenter if gear damage is apparent. Open printer and inspect the
presenter paper path for jammed paper. Remove any jammed paper or other
debris.
590
ERR PRESENTER EXIT JAM
Open printer and inspect the presenter paper path for jammed paper.
Remove any jammed paper or other debris. Restart the cash dispenser. If
the error persist, replace the presenter module.
591
ERR PRESENTER PAPER NOT
DETECTED
Open the printer and verify that the paper is not jamming in the printer
between the printer output and the input to the cutter. Clear all debris from the
printer path. Restart the ATM. If the paper continues to jam, it may be
necessary to replace the cutter or printer. If replacing the printer of cutter
does not clear the error replace the presenter module.
592
ERR SPED DEVICE REPORTED
FAILED
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
593
ERR SPED IN USE
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
594
ERR SPED DEVICE REPORTED
COMM ERROR
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
595
ERR SPED RETURNE INVALID
AMOUNT OF DATA
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
596
ERR SPED INVALID SPED TYPE
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
597
ERR SPED INVALID SPED COMMS
PROTOCOL
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
598
ERR_SPED_INVALID_DEVICE_CLASS Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module.
599
ERR SPED REPORTED
UNRECOGNIZED COMMAND
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
600
ERR SPED REPORTED BLOCK DOES
NOT EXIST
Inspect cable from main board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Verify that the DC
operating voltages are correct. Restart ATM. Clear the error. If error persists,
replace the SPED module