Battery maintenance, Battery low warning, Changing the battery - straight deadbolt – Triton RL1600 User Manual User Manual
Page 50: Changing the battery - swing bolt style
C6
A
PPENDIX
C
Battery Low Warning
Repeated beeping during an opening indicates that the battery is low and needs to be replaced. Triton recommends
replacement of the battery at least twice annually. The battery box is located on the inside of the door.
Note:
If the lock will not operate (i.e. repeated beeping or no beeping) while the door is closed and locked, the
battery must be energized from the two external terminals on the front of the push-button panel.
To energize the lock, connect a 9-volt alkaline battery on the external terminal points. While maintaining contact,
enter a valid combination and turn the dial clockwise to open the lock.
Note: You must maintain battery contact at all times throughout this procedure.
Changing the Battery - Straight Deadbolt
1.
Open the ATM vault door(s). Remove the battery box cover by pulling the
front portion away from the vault door.
2.
The connector is easily removed by unsnapping it from the two (2) terminal
on the top of the battery.
3.
Remove the old battery. Install/connect a new 9-volt alkaline battery.
4.
Push the battery and the leads completely up into the battery compartment.
5.
Reinstall the cover and test the unit several times before closing the vault door.
1.
Grasp the dial fi rmly, and push up 1/4 inch to dislodge the dial
2.
Remove from the Standoff Mounting Bolts
3.
Replace the 9-volt battery
4.
Install the dial by placing on the Standoff Mounting Bolts
5.
Push in a downward direct to engage.
NOTE: Do NOT close the door without checking the operation of the combination and
making certain it is programmed correctly. This style lock WILL auto lock if the door is
closed/latched. If you DO NOT have the Super Master Reset Password programmed
or have misplaced both the Master Password and the Super Master Reset Password,
the lock will require drilling by a certifi ed liscensed locksmith.
Battery Maintenance
Changing the Battery - Swing Bolt Style