Entering the Combination - Both Styles

The electronic lock combination(s) consists of six digits. Upon arrival, the combination(s) of the lock should

already be set at 1-2-3-4-5-6.

After installation of the unit has been completed:
1.

Enter the preset combination and check for proper operation. After each keypress, the lock will beep.

After the fi nal digit has been entered, the lock will beep twice and the open period will begin.
2. Within

four (4) seconds, turn the Straight Deadbolt keypad clockwise to the open position.

3. The Swing Bolt style will retract when the door is opened.

See note: page C6

4.

After the lock is opened, the door may be opened.

Invalid Code Entry - Lock will beep three (3) times. Repeat Steps 1 - 3.

Changing the Combination - Both Styles

** IMPORTANT **

Always perform this operation with the door open.

If your unit is programmed for Dual Code (see Programmable Features), each code must be changed

independently. Follow these instructions for each code change.

To change the combination of the lock:
1.

Enter six (6) zeros.

2.

Enter the current combination (initially set at 1-2-3-4-5-6).

3.

Enter the new six (6) digit combination twice.

- If a mistake is made, wait thirty (30) seconds and repeat steps 1 -3.

4.

Test lock combination several times before closing the door. The combination is now changed.

Valid Code Entry - Double signal after valid six (6) digit code is entered.

Invalid Code Entry - Triple signal and old code is still valid.

Lockout Feature

The lock includes a WRONG TRY PENALTY lockout feature that prevents entry from unauthorized

personnel. This feature performs as follows:

Entry of four (4) consecutive invalid combinations starts a 5-minute delay period.

-

LED

fl ashes RED at ten (10) second intervals.

At the end of the delay period, two (2) more consecutive invalid combinations will restart an additional

5-minute delay. Entry will not respond to a single keystroke during delay period.