Important notice – Star Water Systems S15DC39DR User Manual
Page 2

2
© Copyright 2011 Star Water Systems. All rights reserved.
STAR WATER SYSTEMS
| 95 North Oak St. | Kendallville, IN 46755 | starwatersystems.com
• Installation must be made within a protected area covered
from the elements and freezing. In areas where it is com-
mon practice to bury the unit in the ground, the unit must
be protected from direct sunlight, rain, dust, flooding, snow
and freezing. Failure to do so will void the warranty.
• Check plumbing inlet and outlet to ensure the proper flow
of water through the unit. Match plumbing inlet and outlet
with arrows located on the sides of the valve head and on
the bypass valve (especially if replacing an existing unit).
• Make sure the unit is plugged into a 115 volt grounded
outlet which contains a fuse or circuit breaker of 20 amps
or less.
• Do not run 1/2” I.D. semi-rigid drain tube over 20 running
feet. If over 20 ft., increase drain line tubing size to 3/4”
I.D. for the entire length of tube.
• Initially fill salt brine tank only 3/4 full with salt. (Do not
pack full.)
• If any red rust stains are apparent, mix Super Iron Out® with
the salt. As an alternative, there are types of salt available
that contain iron control agents.
• After installing the unit, manually regenerate unit, follow-
ing the control valve instruction manual.
• Make sure control head is correctly set for your specific
water needs.
• If more than one unit is being installed, the regeneration/
back wash times should be staggered.
IMPORTANT NOTICE
Pay Special Attention to the Following Points
remember, your purchase Is an Investment and
needs to be maIntaIned properly.
If any parts are missing, damaged, unit does not seem to be
working properly, or if you have any questions call
1-800-545-2206 or 1-800-345-9422