Brush replacement, Specifications, Performance – Star Water Systems CF511 (Flint & Walling) User Manual
Page 3

3
© 2011. All rights reserved.
Brush Replacement
Brushes for this pump should be inspected after
every 100 hours of operation.
Pumps with excess of 100 hours of operation may stop operating or
fail to start. This could be due to worn brushes or carbon build-up. The
brushes should be removed and carbon removed. Worn brushes are not
covered under warranty.
1. Disconnect electrical cord from power supply.
2. Remove brush caps with screwdriver.
3. Remove old brush assembly.
4. Insert new brush assembly.
5. Replace brush caps.
For other problems, consult troubleshooting chart.
Motor . . . . . . . . . . . . . 1/2 HP Single Phase, 115V, 60Hz, 8,000 RPM
. . . . . . . . . . . . . . . . . . Series Wound (brush type) AC operation
Maximum Fluid Temperature . . . . . . . . . . . . . . . . . . . . . . . . . .120
°
F
Inlet/Outlet Openings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4” NPT
Maximum Case Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 PSI
SPECIFICATIONS
IL0142
REPLACEMENT PARTS LIST
Ref.
No.
Description
Part
Number
Req’d
Quantity
1
Brush Kit*
015846
1
2
Impeller
and Seal
Kit
020387
Pump
Rev A
1
150380
Pump
Rev B
*Kit includes one pair of brushes.
Shaft Seal
Impeller
Brush Cap
Brush/Spring
Volute Seal
2
1
IN
OUT
PERFORMANCE
Model CF511
0
20
40
60
80
100
120
0
5
10
15
20
25
30
Flow - GPM
Tota
l D
ynam
ic
H
ea
d -
Ft.
IL0153