Spectra Precision Layout Pro Field Software Quick Start Guide User Manual
Page 33
23
5. If you choose
Any Location (see also diagram below):
•
Tap
Next.
•
Tell Layout Pro whether you want to measure elevation
(
Yes/No). If you want to do so, enter the instrument
height (as measured from the ground). Then tap
Next.
•
Set up the instrument at any convenient location from
which you have a good view of the two reference points.
•
Select the first reference point from the plan ([15]).
Have a target placed over this point. Aim the
instrument at this point and shoot it ([16])
•
Repeat the first step for the second reference point
used ([17] and [18]). You then get screen [19] on
which the instrument position is reported to have been
determined. Ensure that the calculated position of the
instrument makes sense compared to the plan.
• Tap
Finish to complete station setup. If you want to
store the point where the instrument is located, first
enable the
Store Instrument Location option, tap Next,
name the point and tap
Finish.
6. If you choose
Use Last Setup, and you tap Next, Layout Pro
will ask you to aim at the reference point to check the
setup you used previously. You may additionally shoot the
reference point to check the angle.
[15]
[16]
[17]
[18]
[19]