Setting Up a Connected Total Station

Before using a total station to perform a stakeout or survey,
you must set up your total station (in the location you want to
shoot from), level it, and turn it on.

If you are using the onboard version of Layout Pro, nothing
else needs to be done.

If you are running Layout Pro on a data collector, connect the
data collector to the total station using a serial cable or
Bluetooth.

Tolerance &

Connection

Settings

To set the parameters on the Layout Pro software:

1. From the main menu, tap

Settings.

2. From the

Layout tab, enter the desired layout tolerance.

3. From the

Instrument tab (the first tab), select the brand

and model of the total station from the

Brand list.

4. Set the parameters on the total station from the settings

recommended in the section below.

Recommended

Settings for

Supported Total

Stations

FOCUS 6, Nikon 300 & 500, Nivo M and DTM/NPL-322

(Tap the menu key on the total station, select Settings, and
select Comm.)

• Ext. Comm (set to NIKON)

• Baud (4800 or match to Layout Pro)

• Length (set to 8)

• Parity (set to none or match Layout Pro)

• Stop Bit (set to 1)

Spectra Precision FOCUS 30 Robotic Total Station

You will typically use a Ranger 3 data collector for controlling
a FOCUS 30 Robotic total station.

1. Turn on both the data collector and the FOCUS 30.

Launch Layout Pro on the data collector.

2. From the main menu, tap

Settings.

3. On the

Instrument tab, select “Spectra Precision” from the

Brand list, and “FOCUS 30” from the Model list (see
screen [1] below).

4. Tap on the

Radio button, This opens the Radio Settings

screen (screen [2] below).