Step 1: Mount pump to tank using flangebolts . Pump output needs to be on the same side as lower
tank outlet ports.
Step 2: Assemble filter assembly and attach to pump inlet side, then attach suction hose with hose clamp to filter
assembly.
Step 3: Install 90 degree barb fitting to lower tank port (See illustration). Attach suction hose with hose clamp to
barb fitting.
Step 4: Install nozzle supply hose to pump output side using hose clamp, . At this point you can install carry handle to tank
using flange bolts .
Step 5: Assemble female disconnect and 1/2” hose barb to 3/8” pvc main supply hose with hose clamp
(See illustration).
Step 6: Assemble items #7, #15, #8 and #12 using hose clamps. (See illustration)
Step 7: Install nozzle bracket to spreader. See pg PW-5 for proper location based on spreader type.
See pg PW-5 for proper location based on spreader type.
Step 8: Mount spray nozzle to nozzle bracket using retainer nut .
Step 9: Connect male disconnect to female disconnect ; complete connection between the pump and the nozzle.
Step 10: Continue to page PW-8 for the electrical power supply portion of the installation.