Hydrostatic tube assembly instructions – SnowEx PWS-225 User Manual
Page 21
![background image](/manuals/364908/21/background.png)
© Trynex International 2010 L1217
AS — 21
Hydrostatic Tube Assembly Instructions
Model # PWS-175/225
REFER TO PAGE AS-20 FOR DIAGRAM
NOTE: All male threads are pre-Teflon taped.
NOTE: V-Maxx Spreader should be in truck during installation.
Step 1: Assemble hydrostatic tube to standpipe
by threading together. Make sure teflon tape is secure and in proper
Step 2: Install straight barb on the tee end of tube assembly facing tank/pump.
Step 3: Connect , , and to hose 13 from Section A (previous instructions) using hose clamp .
Step 4:
Mount the hydrostatic tube assembly to the V-Maxx vertical support (see page AS-4 top photo). Use
conduit clamp and self drilling screw to secure assembly to frame in three places.
Step 5: Install hose barb into hydrostatic tube opposite of the tee end.
Step 6: Install pump cover from section A (previous instructions) using self drilling screw . The cover is
Cut to length hose from section A (previous instructions) between pump manifold and hydrostatic
position.
equalizer tube assembly; connect using hose clamps .
notched to allow hose to pass through both sides.