beautypg.com

Autostart MANUAL TRANSMISSION REMOTE STARTER AS-1785 User Manual

Page 8

background image

P. 8

Installation

Guide

AS-1785

9

PURPLE

(–) External

Trigger

The External Trigger wire can be used for remote-
starting the vehicle with an external device. When

the vehicle is running, triggering this input will

activate Idle Mode. The External Trigger wire can
also be used to operate as a negative trigger with

the Trunk Pin-switch, the Key Sense wire or the

Door Pin-switch:
Option 1 Connects to Negative Trunk Pin. When
this wire is programmed for TRUNK PIN, pressing

TRUNK will activate a 1-second DISARM output. If

ground (-) is detected on the TRUNK PIN (the Trunk
has been opened), an ARM pulse will be sent 5

seconds after the Trunk is closes. An ARM pulse

will be sent 4 seconds after the TRUNK button is

pressed if the Trunk pin state is unchanged (The
Trunk was unopened). DISARM is sent only if the

system was previously locked and armed. If Secure

Lock is enabled, UNLOCK pulse(s) will be sent with

DISARM, a LOCK pulse and a REARM pulse will
be sent when the Trunk is closed or if the Trunk was

left closed.
Option 2 (Default: Engine Start/Stop): The first
Ground (-) pulse on this input will start the Engine,

the second Ground (-) pulse on this input will stop

the Engine.
Option 3 (Key Sense (-) Input): Connects to OEM
Key Sense Wire. When the Key is detected in the

Ignition Switch (Ground (-) signal on the OEM Key

Sense Wire) the Starter Kill will not ARM even when
it is set to Passive Mode. If Secure Lock is

programmed, LOCK and ARM will not be activated

while the Key Sense input is active (“active”

meaning there is a key in the Ignition barrel).

10

WHITE

(–) Ground Out
When Running

This wire provides a constant 500 mA ground output
while the Remote Car Starter is running. This output

becomes active at the same time as the Ignition and
shuts off when the Remote Car Starter shuts down,

e.g.: when the Run Time has expired, when the

STOP button has been pressed, etc. This output

can be used to activate external relays, bypass kits,

etc..