E-10

TROUBLESHOOTING

E-10

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Authorized
Field Service Facility.

Observe Safety Guidelines

detailed in the beginning of this manual.

TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

Poor arc starting when the DC600
is in the CV Sub-Arc or CV
Innershield Modes.

Machine has output but trips off
immediately when wire feed unit
trigger is activated

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1.

Make sure the proper welding
procedures are being used.
(wire feed speed , arc voltage
and wire size)

2.

Check weld cables for loose or
faulty connections.

1. Remove output cables from

DC-600. If problem is resolved
check for external short
between weldiong cables. Also
check control cable (#75, #76,
& #77) for grounds or shorts.

RECOMMENDED
COURSE OF ACTION

WELDING PROBLEMS

DC-600