Undercarriages (K817P, K842)

For easy moving of the machine, optional undercar-
riages are available with polyolefin wheels (K817P) or
a platform undercarriage (K842) with mountings for
two gas cylinders at rear of welder.

Paralleling Kit (K1611-1)

Permits paralleling of two DC-600's for welding cur-
rents of up to 1200 amps, 100% duty cycle.

Tig Module (K930-2)

Portable high frequency generator for AC/DC TIG
welding.

FACTORY OR FIELD INSTALLED
OPTIONS

Multi-Process Switch (K804-1)

The MULTI-PROCESS SWITCH gives you the ability
to:

Switch between "stick welding or air/carbon arc
cutting" and using a semi-automatic or automatic
wire feeder.

Change the polarity of a semi-automatic or auto-
matic wire feeder without changing any electrical
cable connections.

See Figure C.1

FIGURE C.1 - MULTI-PROCESS SWITCH

C-1

ACCESSORIES

C-1

+

WIRE

FEEDER

CABLES

STICK OR

AIR/CARBON

ARC CABLES

STICK OR

AIR

CARBON

ARC

+

-

DC-600

WIRE FEEDERS AND TRACTORS

The DC-600 can be used to power any of the follow-
ing Wire Feeders and Tractors:

Semi-Automatic Wire Feeders:

DH-10

LN-9

LN-7

LN-9 GMA

LN-7 GMA

LN-23P

LN-742

LN-25

LN-8 LN-10

Automatic Wire Feeders:

NA-3

NA-5R

NA-5

Tractors:

LT-7

LT-56

FIELD INSTALLED OPTIONS

Remote Output Control (K775 or K857
with K864 Adapter)

An optional

remote out control

is available. The

K775 is the same remote control that is used on other
Lincoln power sources. The K775 consist of a control
box with 28 feet (8.5mm) of four conductor cable. This
connects to terminals 75,76, and 77 on the terminal
strip (T.S.1) and the case grounding screw so marked
with the symbol

on the machine. These termi-

nals are located behind the hinged cover on the case
front. This control will give the same control as the
output control on the machine.

The K857 is similar to the K775, except the K857 has
a 6-pin MS-style connector. The K857 requires a
K864 adapter cable which connects to the 14-pin con-
nector on the case front.

Remote Control Adapter Cable (K864)

A "V" cable 12" (.30 m) long to connect a K857
Remote Control (6-pin connector) with an LN-7 wire-
feeder (14-pin connector) and the machine (14-pin
connector). If a remote control is used alone the wire-
feeder connection is then not used.

S T R A I G H T P L U G ( 1 4 P I N )
T O P O W E R S O U R C E

C A B L E R E C E P T A C L E ( 6 S O C K E T )

C A B L E R E C E P T A C L E ( 1 4 S O C K E T )

T O : K 8 5 7 R E M O T E C O N T R O L