background image

DC-600

A-4

INSTALLATION

A-4

RECONNECT PROCEDURE

Multiple voltage machines are shipped connected to
the highest input voltage listed on the machine’s rating
plate. Before installing the machine, check that the
Reconnect Panel in the Input Box Assembly is con-
nected for the proper voltage.

Failure to follow these instructions can cause immedi-
ate failure of components within the machine.

__________________

To reconnect a multiple voltage machine to a different
voltage, remove input power and change the position
of the reconnect board on the Reconnect Panel.
Follow The Input Connection Diagram located on the
inside of Case Back Input Access Door. This connec-
tion diagram for the following code is shown below.

1.

For 230/460/575, see Figure A.3. (M15666)

CAUTION

FIGURE A.3-Reconnect Panel Board Positions for 230/460/575 VAC Machines