TECHNICAL SPECIFICATIONS - Ranger 200 (K1724-1)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
System
Kohler
1 cylinder Low Idle 2500
26 cu. in
12VDC Battery &
Fuel: 12 gal.
Command (Cast Iron Liner) Starter
CH15 OHV
15 HP @
(426 cc)
(Group 58; 435
45.4 L
3600 RPM High Idle 3700
cold crank amps)
Bore x Stroke
Battery Charger
Oil: 2.0 Qts.
15 A. regulated
1.9 L
Full Load 3500
2.55” x 2.64”
(90 mm x 67mm) (Push Button Start)
INPUT - GASOLINE ENGINE
RATED OUTPUT - WELDER
HEIGHT
WIDTH
DEPTH
WEIGHT
30.00 in.
21.50 in.
42.25 in.
409 lbs.
762.0 mm
546.0 mm
1073.0 mm
186 kg.
LUBRICATION
VALVE LIFTERS
FUEL SYSTEM
GOVERNOR
Full Pressure
Hydraulic
Mechanical Fuel Pump
Mechanical Governor
with Full Filter
5% Regulation
AIR CLEANER
ENGINE IDLER
MUFFLER
ENGINE PROTECTION
Duel Element
Automatic Idler
Low noise Muffler: Top outlet Shutdown on low oil
can be rotated. Made from pressure.
long life, aluminized steel.
ENGINE WARRANTY: 2 year unlimited hours (See engine manufacturer warranty for details.)
OUTPUT - GENERATOR
Welding Output
Volts at Rated Amps
Duty Cycle
Max. OCV @ 3700 RPM
CC DC Constant Current 210 amps
25 volts
100% 80 volts RMS
CC Output Range 40 to 210 amps
Auxiliary Power
1
6,000 Watts, 60 Hz
120/240 Volts
100 % Duty Cycle
PHYSICAL DIMENSIONS
ENGINE COMPONENTS
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
Cooling System:
Air-Cooled