beautypg.com

Troubleshooting, Caution – Lincoln Electric IM827 POWER FEED 10M WIRE FEEDER User Manual

Page 63

background image

E-7

TROUbLESHOOTING

E-7

POWER FEED

®

10M SINGLE WIRE FEEDER

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Display shows any of the following:

Err 211

Microprocessor RAM error in
Control Box.

Turn Power off at power source.
Wait 5 seconds. Turn power back
on. If Err 211 is displayed again,
then replace CB mother PC board.

Err 212

Microproceeor RAM Error in object
board other than Control Box (Such
as feed head)

Cycle power as in Err 211. If Err
212 is still displayed, then replace
PC board in the object with fault.
The object with the fault should be
solid red on its status LED.

--- (THREE DASHES)

Appears on right display of CB mod-
ule that contains the status Led

Dashes indicate that the encoder
does not control anything including
on/off output control.

Observe all Safety Guidelines detailed throughout this manual

Error Codes for the Power Wave

®

455: Code 10555 and below

Note: For any Err # listed below write down the error number for refference and try cycling power to see if the
error clears itself. If not, refer to what the What to Do column for the given Err.

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION