beautypg.com

Accessories, L9777 wire feed unit dimension print, Figure d.2 – Lincoln Electric IM542 INVERTEC POWER WAVE 450 ROBOTIC User Manual

Page 42: D-2 power wave 450, Check coolant level. add more if required

background image

ACCESSORIES

D-2

D-2

POWER WAVE 450

1.00

6.25

6.75

4.67

REMOTE

A

6.67

7.16

7.50

1.72

3.18

.25

.25

.281

7.00

11.25

1.44 TYP.

OUTLET

1.31

.81

1.00

8.06

.87

INLET

INPUT

3.36

6.21

GAS FITTING

MOUNTING WIRE FEED UNIT)

(10 HOLES FOR

CONNECTOR

CLOSED

TRIGGER

CONNECTOR

CONNECTOR

GAS FITTING

DIRECTION

WIRE FEED

TOP VIEW

CLEARANCE ENVELOPE OF QUICK RELEASE ARMS

L

C

OF WIRE

C

L

OF WIRE

L

C

OF WIRE

GUN CABLE FITTING

7.69

2.90

SWING ARM

L9777

L9777 WIRE FEED UNIT DIMENSION PRINT

4. Check coolant level. Add more if required.

Figure D.2

Do Not Use: Any prepacked welding industry coolant
mixture, such as those offered by Miller, OKI,
Bernhard, or Dynaflux. These coolants contain sub-
stances which attack plastic components and may
shorten the life of the system. Once added, these sub-
stances are virtually impossible to purge from the sys-
tem. DO NOT USE OIL-BASED COOLANTS OF ANY
TYPE.

0.25 to 0.50
inches

Visible Coolant Level

Rear Panel of
Power Wave

Reservoir Screen

FOR THE LATEST

SYNERGIC 7F

INFORMATION

CONSULT IM559.