Robotic interface, Robot controller setup – Lincoln Electric IM542 INVERTEC POWER WAVE 450 ROBOTIC User Manual
Page 39

5. ROBOT CONTROLLER SETUP
5.1 WELD SYSTEM SETUP
MONITORING FUNCTIONS
1
Arc loss
ENABLED
2
Gas shortage
DISABLED
3
Wire shortage
DISABLED
4
Wire stick
ENABLED
5
Power supply failure
ENABLED
6
Coolant shortage
ENABLED
WELD RESTART FUNCTION
7
Return to path
DISABLED
8
Overlap distance
0mm
9
Return to path speed
200mm/s
SCRATCH START FUNCTION
10
Scratch start
DISABLED
11
Distance
5mm
12
Return to start speed
12mm/s
ON-THE-FLY FUNCTION
13
On-The-Fly
ENABLED
14
Voltage increment
1.0V
15
Wire feed increment
5.0IPM
16
Current increment
5.0A
OTHER FUNCTIONS
17
Weld from teach pendent
ENABLED
18
Run in
DISABLED
19
Wire burnback/retract
DISABLED
5.2 WELD EQUIPMENT SETUP
1
Weld process
MIG
2
Remote arc enable
DI 0
3
Weld power control
Wire FD
4
Wire feed control
AO
5
Wire+ Wire- speed
80IPM
6
Wire feed speed units
IPM
WELD RUN IN
7
Voltage
50.0V
8
Current
250.0A
9
Wire feed
200IPM
10
Time
0.00s
WIRE BURNBACK/RETRACT
11
Voltage
50.0V
12
Current
250.0A
13
Wire feed
0IPM
14
Time
0.00s
TIMING
15
Arc start error time
2.00s
16
Arc detect time
0.10s
17
Arc loss error time
0.30s
18
Gas detect time
0.05s
19
Gas purge time
1.00s
20
Gas preflow time
0.50s
21
Gas postflow time
0.00s
WIRE STICK FUNCTION
22
Reset
DISABLED
23
Reset tries
1
24
Voltage
50.0V
25
Time
0.00s
VOLTAGE OUTPUT SCALING
26
Minimum reference
0.60V
27
Maximum reference
9.60V
28
Minimum output
50.0V
29
Maximum output
150.0V
CURRENT OUTPUT SCALING
30
Minimum reference
0.00V
31
Maximum reference
10.00
32
Minimum output
0.0A
33
Maximum output
400.0A
WIRE FEED SPEED OUTPUT SCALING
34
Minimum reference
0.60V
35
Maximum reference
9.60V
36
Minimum output
50IPM
37
Maximum output
770IPM
VOLTAGE INPUT SCALING
38
Minimum reference
0.0219V
R = 7.268 (7.620)
39
Maximum reference
7.289V
ZERO ~ 0.020
40
Minimum output
0.0V
41
Maximum output
80.0V
CURRENT INPUT SCALING
42
Minimum reference
0.7848V
R = 8.32 (8.317)
43
Maximum reference
9.104V
ZERO =0.58 - 0.80
44
Minimum output
0.0A
45
Maximum output
750A
5.3 SYSTEM VARIABLES
$AWEUPR $WSTK_ENA_DLY
0.10s
5.4 TOUCH SENSING SETUP
Sensor port type
WI
Sensor port number
1
Circuit port type
WO
Circuit port number
3
ROBOTIC INTERFACE
C-5
C-5
POWER WAVE 450
APR97