beautypg.com

Installation, Rated output, Output – Lincoln Electric IM542 INVERTEC POWER WAVE 450 ROBOTIC User Manual

Page 11: Recommended input wire and fuse sizes, Physical dimensions

background image

POWER WAVE 450

TECHNICAL SPECIFICATIONS - POWER WAVE 450

INPUT - THREE PHASE 50/60 HZ. ONLY

Input Voltages:

200

230

400

460

575

Input Currents

@ 500A/40 VDC

87

76

44

38

32

@ 450A/38 VDC

75

65

38

32

28

RATED OUTPUT

Duty Cycle

Amps

Volts at Rated Amperes

200 - 60% Duty Cycle

500

40 VDC

230/400/460 - 60% Duty Cycle

500

40 VDC

460/575 - 60% Duty Cycle

500

40 VDC

200 - 100% Duty Cycle

450

38 VDC

230/400/460 - 100% Duty Cycle

450

38 VDC

460/575 - 100% Duty Cycle

450

38 VDC

OUTPUT

Constant Open

Continuous

Process

Circuit Voltage

Current Range

Current Ranges

75 Volts

5-540 Amps

GMAW 50-540 Amps

FCAW 40-540 Amps
STICK 30-540 Amps

Pulse

Pulse

Pulse and Background

Pulse

Current Range

Voltage Range

Time Range

Frequency

5-750 Amps

5-55 Volts

100 Microsec - 3.3 Sec

0.15 - 1000 Hz

RECOMMENDED INPUT WIRE AND FUSE SIZES

Type 75°C

Type 75°C

Type 75°C

Input

Duty

Input Ampere

Copper Wire in

Ground Wire in

(Super Lag)

Voltage/

Cycle

Rating on

Conduit

Conduit

or Breaker

Freqency

Nameplate

AWG[IEC]

AWG[IEC]

Size (Amps)

Sizes (MM

2

)

Sizes (MM

2

)

200/50-60

60%

87

4 (25)

8 (10)

120

230/50-60

60%

76

4 (25)

8 (10)

100

400/50-60

60%

44

8 (10)

10 (6)

50

460/50-60

60%

38

8 (10)

10 (6)

50

575/50-60

60%

32

8 (10)

10 (6)

50

200/50-60

100%

75

4 (25)

8 (10)

100

230/50-60

100%

65

4 (25)

8 (10)

100

400/50-60

100%

38

8 (10)

10 (6)

50

460/50-60

100%

32

8 (10)

10 (6)

50

575/50-60

100%

28

8 (10)

10 (6)

40

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

905 mm

515 mm

1010 mm

138 kg

35.6 in.

20.3 in.

39.8 in.

304 lbs.

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C