Figure 4: relative (%) group size – Hired-Hand Evolution Series Bird Scale Manual User Manual
Page 35

Part n° 890-00487 rev.00
Evolution Bird Scale Controller
35
Relative Group Size (%)
The groups can be based on the weight interval (in %) that separate the
bird weighings from the average weight. This mode perfectly suits the
birds' growth since it avoids having to change the weight limits as the birds
are growing.
Example = 1 000g (1kg)
%
[ Example :+/- 10 % from
the Average Weight ]
OVERWEIGHT 2
OVERWEIGHT 1
AVERAGE GROUP
UNDERWEIGHT 1
UNDERWEIGHT 2
HEAVY
LIGHT
Additional group size 1 = 12%
Additional group size 2 = 20%
Average group size = 10%
EXAMPLE
G
1
G
2
A
[ Example : 1-12 % above
the average group ]
[ Example : 1-20 % above
OverWeight group 1 ]
[ Example :above
OverWeight group 2 ]
[ Example : 1-12 % below
the average group ]
[ Example : 1-20 % below
UnderWeight group 1 ]
[ Example: below
UnderWeight group 2 ]
AVERAGE
WEIGHT = 100 %
G
2
A
v
er
a
g
e
=
10
%
1 050 g
1 170 g
1 370 g
950 g
830 g
630 g
G
2
=
20 %
G1
=
1
2
%
G1
=
1
2
%
G2
=
2
0
%
Figure 4: Relative (%) Group Size
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)