beautypg.com

Program 2,0 a b, Program 2,1 a b, Program 2,2 a b – Hired-Hand System 500 Programs (Conventional Model) User Manual

Page 3: Program 2,3 a b

background image

System 500 Power Curtain Controller (Conventional) Program Sheets

Rev 7/97

4801-2977

Program 1,6

A

B

Stage

Mode

Sensor(s) Differential

Offset

Stage

Mode

Sensor(s) Differential

Offset

1

Heat

3

2

0

1

Heat

3

2

4

2

Cool Stir

3

1

9

2

Cool Stir

3

1

9

3

Cool Stir

3

1

14

3

Cool Stir

3

1

14

4

Cool Stir

3

1

16

4

Cool Stir

3

1

16

5

Cool Stir

3

1

18

5

Cool Stir

3

1

18

6

Cool Stir

3

1

20

6

Cool Stir

3

1

20

7

Cool Stir

3

1

22

7

Cool Stir

3

1

22

8

Cool Stir

3

1

24

8

Cool Stir

3

1

24

Initial Drop

40

Initial Drop

40

Sensor(s)

3

Sensor(s)

3

Degrees above Target

6

Degrees above Target

3

Program 2,0

A

B

Stage

Mode

Sensor(s) Differential

Offset

Stage

Mode

Sensor(s) Differential

Offset

1

Heat

1

1

2

1

Heat

1

1

2

2

Heat

2

1

40

2

Heat

2

1

2

3

Cool Neg

1

1

2

3

Cool Neg

1

1

2

4

Cool Neg

2

1

10

4

Cool Neg

2

1

2

5

Cool Stir

1

1

10

5

Cool Stir

3

1

4

6

Cool Stir

3

1

15

6

Cool Stir

3

1

6

7

Cool Stir

3

1

15

7

Cool Stir

3

1

8

8

Cool Stir

3

5

20

8

Cool Stir

3

5

10

Initial Drop

25

Initial Drop

25

Sensor(s)

1

Sensor(s)

3

Degrees above Target

3

Degrees above Target

3

Program 2,1

A

B

Stage

Mode

Sensor(s) Differential

Offset

Stage

Mode

Sensor(s) Differential

Offset

1

Heat

2

2

1

1

Heat

2

2

1

2

Heat

3

2

1

2

Heat

3

4

2

3

Cool Neg

1

2

1

3

Cool Neg

1

2

1

4

Cool Neg

2

2

1

4

Cool Neg

2

2

1

5

Cool Stir

3

2

1

5

Cool Stir

3

3

1

6

Cool Stir

3

2

2

6

Cool Stir

3

2

2

7

Cool Stir

3

2

4

7

Cool Stir

3

2

4

8

Cool Stir

3

6

6

8

Cool Stir

3

6

6

Initial Drop

40

Initial Drop

40

Sensor(s)

3

Sensor(s)

3

Degrees above Target

3

Degrees above Target

3

Program 2,2

A

B

Stage

Mode

Sensor(s) Differential

Offset

Stage

Mode

Sensor(s) Differential

Offset

1

Heat

3

3

0

1

Heat

3

3

0

2

Heat

3

3

2

2

Heat

3

3

2

3

Cool Stir

3

1

2

3

Cool Stir

3

1

2

4

Cool Stir

2

1

2

4

Cool Stir

2

1

2

5

Cool Stir

3

1

4

5

Cool Stir

3

1

4

6

Cool Stir

3

1

4

6

Cool Stir

3

1

4

7

Cool Stir

3

1

6

7

Cool Stir

3

1

6

8

Cool Stir

3

1

6

8

Cool Stir

3

1

6

Initial Drop

40

Initial Drop

40

Sensor(s)

3

Sensor(s)

3

Degrees above Target

3

Degrees above Target

3

Program 2,3

A

B

Stage

Mode

Sensor(s) Differential

Offset

Stage

Mode

Sensor(s) Differential

Offset

1

Heat

3

2

1

1

Heat

3

2

1

2

Heat

3

2

1.5

2

Heat

3

2

1.5

3

Cool Stir

3

1

2

3

Cool Neg

3

1

2

4

Cool Stir

3

1

3

4

Cool Neg

3

1

3

5

Cool Stir

3

2

12

5

Cool Stir

3

2

12

6

Cool Stir

3

4

18

6

Cool Stir

3

4

18

7

Cool Stir

3

1

5

7

Cool Stir

3

1

5

8

Cool Stir

3

1

6

8

Cool Stir

3

1

6

Initial Drop

40

Initial Drop

40

Sensor(s)

3

Sensor(s)

3

Degrees above Target

5

Degrees above Target

5