5

.

HYST2.H

±XXXXX0

Hysteresis upper trip point 2 value.

HYST2.L

DESCEND
ASCEND

Hysteresis lower trip point 2 applies to descending data.
Hysteresis lower trip point 2 applies to ascending data.

HYST2.L

±XXXXX0

Hysteresis lower trip point 2 value.

7. FRONT PANEL TRIP STATUS INDICATION:

Display select: The Trip Status can be monitored in the run mode by using the
“DISPLAY” key to step to the trip status display. The units will only be displayed
momentarily when changed by the unit selection key.

Setup: Can be set in configuration for two types of display indications under the
“DISPLAY” parameter for “TRIP” or “ACCEPT”.

• "TRIP" indication, the alpha display will indicate the trip out active status.

“TRIP”

No Trip outputs active

“TRIP 1”

Trip out 1 active

“TRIP 2”

Trip out 2 active

“TRIP 1 & 2"

Trip out 1 and 2 active

Note: Trip status is affected by the output polarity setting of “UNDER” or
“OVER”.

• “ACCEPT” indication, the alpha display will indicate "LOW', "ACCEPT" and

"HIGH" for trip band 1. This type of indication is only applicable to the “BAND”
type Trip 1. Trip Band 2 should be set to “OFF”.

“LOW”

Below Trip Band

“ACCEPT”

In Trip Band

“High”

Above Trip Band

Note: Trip status is NOT affected by the output polarity setting of “UNDER” or
“OVER”.

8. FRONT PANEL TRIP POINT MONITOR AND ENTRY:

MENU SETUP:

The trip points can be viewed or modified from the front panel

when set in the “TRIP PT” menu.

View: Enables the unit for front panel viewing by setting the "DISPLAY"

parameter to "VIEW" in the "TRIP PT” Menu". With this setting the Trip Point
Values can be recalled but not modified.

Modify:

Enables the unit for front panel viewing and entry by setting the