Condec DLR334 Series User Manual
Page 13

APPENDIX B - INSTALLATION
B-1
.
INSTALLATION
The Relay Option Board
(KKY8924-1) is mounted
to the CPU bd. assy.
on standoffs as shown.
(10) m/f _” standoffs (2per)
(5) panhead screws
WIRING:
KKY8924-1 BOARD TO CPU BOARD WIRING:
♦
Connect the 20 conductor ribbon cable between J5 EXPANDER on the CPU
assy. (KKR8924-) to J1 on the Analog/Relay/RPM assy. (KKY8924-1).
* Be sure to connect the ribbon cable so that pin 1 of J5 connects to pin 1 of J1.
♦
The two wire red and black cable provides power to the analog assy. The single
in-line plug of this cable plugs into J6 on the CPU assy. (KKR8924 -) and the
black and red wires are terminated at TB2 on the assy.
KKY8924-
BOARD
WIRE COLOR
CPU
BOARD
+V
TB4-4
Red wire
J6-1
COM
TB4-5
Black wire
J6-2
-V
TB4-6
White wire
J6-4