Condec DLR334 User Manual
Page 7
![background image](/manuals/361800/7/background.png)
PAGE 7
74845
COMMAND CODE SUMMARY TABLE II
COMMAND
RESPONSE
D
DESCRIPTION
OSR
OSR
{o1|o2}
3
Output status recall. :later
DISPLAY:
MPD
ACK
-
Display to Max mode. ;later
MMD
ACK
-
Display to Min mode. ;later
UNITS:
UxD
ACK
-
Conv. Select units (x=A,B,C etc. per
Table III)
UUE
{unit1| unit2}
ACK
1
Base ‘Cal’ units entry.
UUR
UUR
{unit1|unit2}
3
Base ‘Cal’ units recall.
PRINT:
PRD
ACK
-
Print to printer Port 2. ;later
CAPACITY:
CPE
{cap}
ACK
6
Capacity entry.
CPR
CPR
{cap}
6
Capacity recall.
REE
{res}
ACK
5
Resolution entry.
RER
RER
{res}
5
Resolution recall.
CALIBRATION:
ZCD
ACK
6
Perform zero cal.
RxD
ACK
Perform linear reset at span x;
Where x is a # from 1 – 9 or letter
‘a’.
HCE
{data}
ACK
166 Perform hysteresis correction.
LxE
{data}
ACK
6
Perform linear cal at point x; Where
x is a # from 1 – 9 or the letter ‘a’
(linear on).
ZFE
{x1|c1}
ACK
17
Zero cal correction entry.
ZFR
ZFR
{x1/c1}
17
Zero cal correction recall.
LXE
{x1|---x9|xA}
ACK
89
Span cal linear corr. All X’s entry.
LXR
LXR
{x1|---x9|xA}
89
Span cal linear corr. All X’s recall.
LFE
{x1|---x9|xA}
ACK
89
Span cal linear corr. All S’s entry.
LFR
LFR
{x1|---x9|xA}
89
Span cal linear corr. All S’s recall.
LCE
{x1|---x9|xA}
ACK
89
Span cal linear corr. All C’s entry.
LCR
LCR
{x1|---x9|xA}
89
Span cal linear corr. All C’s recall.
HFE
{x1|c1}
ACK
17
Hysteresis (X and C) corr. Entry.
HFR
HFR
{x1|c1}
17
Hysteresis (X and C) corr. Recall.
SETUP DATA:
SUE
{d/s|---min}
ACK
13
SUR
SUR
{d/s|---min}
13
Main pressure setup recall.
FLE
{fil}
ACK
Filter setup entry.
FLR
FLR
{fil}
Filter setup recall.
INE
{I1|I2}
ACK
Input setup entry.
INR
INR
{I1|I2}
Input setup recall.
P2E
{s1|---s7}
ACK
Port 2 serial setup entry.
P2R
P2R
{s1|---s7}
Port 2 serial setup recall.
TME
{hhmm}
ACK
Time entry.
TMR
TMR
{hhmm}
Time recall.
DTE
{mmddyy}
ACK
Date entry.
DTR
DTR
{mmddyy}
Date recall.
TIE
{time/date}
ACK
Time and Date setup entry.